background image

Symbols

 

Conforms to EU directives.

 

 

Equipment protected by double or reinforced insulation.

 

 

See operator’s guide.

 

For indoor use only.

 

Separate collection for electrical and electronic equipment.

•  Do not attempt to repair this equipment as there are no user serviceable parts in this equipment. Opening the back cover will   
  expose potentially lethal voltages. Refer all repairs to the manufacturer or qualified service center.

Dispose of waste electrical and electronic equipment.

In order to preserve, protect and improve the quality of environment, protect human health and utilise natural 

resources prudently and rationally, the user should return unserviceable product to relevant facilities in accordance 

with statutory regulations. The crossed-out wheeled bin indicates the product needs to be disposed separately and not 

as municipal waste.

Disposal of used batteries/accumulators!

The user is legally obliged to return used batteries and accumulators. Disposing used batteries in the household waste 

is prohibited! Batteries/accumulators containing hazardous substances are marked with the crossed-out wheeled bin. 

The symbol indicates that the product is forbidden to be disposed via the domestic refuse. The chemical symbols for 

the resective hazardous substances are 

Cd

 = Cadmium, 

Hg

 = Mercury, 

Pb

 = Lead.

You can return used batteries/accumulators free of charge to any collecting point of your local authority, our stores, or 

where batteries/accumulators are sold. Consequently you comply with your legal obligations and contribute to 

environmental protection.

Warranty Statement:

This tester is warranted to the original purchaser against defects in material and workmanship for two years from the date of 

purchase. During this warranty period, IDEAL INDUSTRIES (U.K.) Ltd. will at its option replace or repair the defective unit, 

subject to verification of the defect or malfunction. This warranty does not cover fuses, batteries or damage from abuse, neglect, 

accident, unauthorized repair, alteration, or unreasonable use of the instrument.
Any implied warranties arising out of the sale of an IDEAL product, including but not limited warranties of merchantability and 

fitness for a particular purpose, are limited to the above. The manufacturer shall not be liable for loss of use of the instrument 

or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, 

expenses or economic loss.

Country laws vary, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, 

and you may also have other rights which vary from country to country.

IDEAL INDUSTRIES (U.K.) Ltd. 

Unit 3, Europa Court, Europa Boulevard, Westbrook, Warrington, 

Cheshire, WA5 7TN, United Kingdom 

+44-(0)1925-444446 Customer Assistance 

www.idealindustries.co.uk

Made in China

SPECIFICATIONS:

Operating Range:  

200-250VAC 

Operating Frequency:  

47-63Hz

Pulse:  

16A (10

µ

s)

Maximum Load: 

1.25W @ 240VAC

Duty Cycle:   

10µs every 16.6ms (continuous), (0.06%)

Weight (excluding battery):  Transmitter approx 50 g., Receiver approx. 85 g.
Power Supply:  

Transmitter powered from 230V supply, Receiver 9VDC battery 

Operating Temperature:  

0 to 50ºC 

Certification: 

EN61010-1, CATII-300V

N12966

Locating a Circuit Breaker or Fuse:

1.  Plug the IEC-320 end of the supplied mains cord into the transmitter. 

2.  Plug the other end of the mains cord into the AC socket. Go to the circuit  breaker 

  panel or consumer unit.

3.  Turn the receiver on, and allow it to complete its self-test away from power.

4.  Place the flat surface of the tapered end of the receiver directly onto the circuit

  breaker or fuse as shown in Fig A. Depending on the breaker type, the receiver may

  have to be turned 90° in order to obtain an accurate reading.

5.  Move the receiver down each side of the panel passing over each breaker or fuse. 

  This will calibrate the receiver to the signal from the transmitter.

6.  Move the receiver down each side once more. On the second pass, the receiver will 

  continually beep and the green LED will flash when positioned over the correct circuit breaker i.e. the breaker powering the 

transmitter. Some signals will be detected on the first pass. Note: In certain circumstances, it may be difficult to identify 

the correct breaker due to wire routing in the panel. If adjacent breakers cause the receiver to beep continually, remove the 

panel cover (whilst observing safe working practices) and hold the tapered end of the receiver against the wires leading to 

the breakers in question. Separate the wires if possible to reduce bleeding of the signal from one wire to the next. This way 

cross-over signals can be eliminated allowing accurate identification of the correct breaker. 

7.  Trip the breaker off and check that the LED’s on the transmitter are now off, confirming that you have selected the correct 

breaker or fuse to turn off.

Locating a Circuit Breaker or Fuse Connected to a Light Fixture

1.  Disconnect the electrical supply to the light fixture or take suitable safety precautions when connecting to live unshielded 

contacts.

2.  Remove the ceiling rose or light fixture cover. 

3.  Plug the 61-184EU test lead set (not included) into the transmitter. Using the crocodile clips supplied with the 61-184EU, 

  connect the brown test lead to the light fixture’s live contact, the blue to neutral and the green to earth. 

4.  Turn the electrical supply to the light fixture back on. 

5.  If the light fixture is controlled by a wall switch, make sure the wall switch is ON.

6.  Follow the procedure described in Locating a Circuit Breaker or Fuse steps 3 through 7.

Receiver Auto Power Off:

If the receiver is left on and not utilized for 10 minutes (no energised AC circuit or transmitter signals are detected), it will 

automatically shut down to conserve its battery life.

Battery Replacement:

Remove battery cover. Insert new 9V battery into battery compartment and re-install battery cover.

Checking Sockets for Correct Wiring:

1.  Plug the IEC-320 end of the supplied mains cord into the transmitter. 

2.  Always test the transmitter’s socket test function by plugging the other end of the mains cord into a known live socket before 

and after use. All three LED’s on the transmitter should light indicating a correctly wired live socket.

3.  Plug the mains cord into the live socket you wish to test. The three LED lamps on the transmitter will indicate the wiring 

configuration of the socket. The label on the transmitter provides a key to various fault conditions. 

4.  If power to the socket is switched off, all three LED’s will go out.
Key to possible fault conditions:
 

LED ON 

LED OFF

 

CORRECT WIRING

 

OPEN EARTH

 

LIVE NEUTRAL REVERSE

 

OPEN LIVE

 

OPEN NEUTRAL

 

LIVE EARTH REVERSE

 

WARNING 

: This equipment will not detect a Neutral / Earth reversed condition.

The “Socket Tester” feature was designed for use on UK wiring systems that 

typically have fixed polarity. Additional care must therefore be taken when using 

the supplied European style power cord because polarity is determined by the 

orientation of the 2-pin Euro plug in the wall outlet being tested. The transmitter’s 

LEDs may not therefore indicate the actual wiring configuration!

Fig. A

61-534EU

Digital Circuit Breaker Finder

and Socket Tester

The task of locating AC circuits is now made quick and easy. No more guessing or 

trial and error when it comes to locating the correct circuit breaker or fuse supplying 

power to an AC  socket or lighting fixture*. Common wiring faults are instantly 

identified with the integrated socket tester. 
*Requires optional test lead set (61-184EU).

 

WARNING: 

For indoor use only. 

Use extreme care when working around AC circuits, severe shock hazards 

exist. Familiarize yourself with these instructions prior to use and always 

check that the transmitter and receiver are operating properly before using 

on live circuits. Always verify the integrity of the 13A fuse located inside the

plug top which is attached to the supplied UK power cord. If used on a circuit 

controlled by a dimmer, turn the dimmer to the highest on position. Do not 

use in cardiac care areas. 

WARNING: This equipment will not detect a Neutral / Earth reversed 

condition. The “Socket Tester” feature was designed for use on UK 

wiring systems that typically have fixed polarity. Additional care 

must therefore be taken when using the supplied European style 

power cord because polarity is determined by the orientation of 

the 2-pin Euro plug in the wall outlet being tested. The transmitter’s 

LEDs may not therefore indicate the actual wiring configuration!

Features:

 

•  Automatically and quickly finds correct breaker or fuse

•  Optional test lead set available for use at bare wires

  and light fixtures (61-184EU)

•  Non-contact voltage sensor for 80-300VAC

•  Transmitter works on 230VAC circuits

•  Socket tester feature verifies wiring configuration

•  Low battery detection

OPERATION:

Self-Test

Push the receiver’s power switch forward to the ON position. The unit will perform a self-test to ensure proper operation.

Low Battery Detection

After performing the self-test the receiver will verify the voltage of the 9VDC battery. If the battery voltage is below 7.3 volts, the 

receiver will beep three times and turn itself off. Remove the old battery, and replace it with a standard 9VDC battery.

Idle Mode

Provided the battery is good, the receiver will enter the idle mode.  Both the receiver’s LEDs will remain on and the receiver will 

continually check for any active signals.

Non-Contact Voltage Test

Point the receiver’s nose towards a live AC socket or power cord. Once an AC Voltage field of > 50V is sensed, the receiver will 

switch to Voltage Sensor mode. The red LED remains lit and the receiver will audibly beep. The beeping speed will increase when 

the receiver is moved closer to the AC power source, and slows when the receiver is moved further away. Once the receiver 

senses a signal from the transmitter, it will switch to the circuit identifier mode. The circuit identifier mode is indicated by a 

steady green LED. To leave this mode and use the receiver for AC Voltage detection, turn the power switch off, then on again.

Receiver

Supplied with 61-534EU

WARNING: THIS EQUIPMENT 

WILL NOT DETECT A 

NEUTRAL-EARTH 

REVERSED CONDITION

Transmitter for 

61-534EU

CORRECT WIRING

OPEN EARTH

LIVE NEUTRAL REVERSE

OPEN LIVE

OPEN NEUTRAL

LIVE EARTH REVERSE

WIRING INDICATIONS

®

USE THIS SIDE UP

Power Switch

Battery Compartment

Red LED

Green LED

If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment 

may be impaired. 

IEC 320-Plug

Transmitter