Gas Shock Removal/Installation Instructions 

 

 

 

 

 

 

 

 

   

 

                                                                                                                        

 

 

 

 

 

 

 

 

 

 

 

 

Step 1: 

Post safety warning and barricade work area, to prevent unauthorized use of the area while service 

work is being performed. 

 

Step 3: 

Locate the top channel nut and bolt assembly for the gas shock 

(located under the top channel assembly). Using a 14mm (or 

9/16”) deep socket and ratchet on the bolt head and a 14mm (or 

9/16”) deep socket on the nut, loosen the assembly completely. 

Remove nut and bolt (save for re-use). 

 

 

Step 4: 

Using a forklift (recommended) or 2 people (one on each side), lift 

the top channel assembly off the lower tube assembly. Place the 

top channel assembly in a safe location for re-use later. 

 

 

 

 

Step 5: 

Locate the lower nut and bolt assembly for the gas shock, (located 

at center of the lower tube assembly).  Using a 14mm (or 9/16”) 

deep socket and ratchet on the bolt head and a 14mm (or 9/16”) 

deep socket on the nut, loosen the assembly completely.  

Remove nut and bolt assembly (save for re-use). 

 

Note:

 Do not over tighten. 

 

 

 

 

 

  

Step 2: 

Ensure the Stand is in a vertical upright position. Remove and store the locking pin. Allow the Stand to 

rise to its maximum raised position (as high as the unit will go). 

Down 

 

UP  