12
FLOW CARTRIDGE REPLACEMENT
A 4740 AA, A 4741 AA & A 6385 AA
A 5637 AA
To replace the flow control cartridge:
(REMEMBER TO TURN OFF WATER SUPPLIES)
1. Prise out the index button.
2. Remove handle screw.
3. Pull off the flow control handle.
4. Pull of handle carriers.
5. Unscrew cartridge with 17mm
A/F spanner and replace if
necessary.
1. Unscrew dog point screw and
pull off flow control handle.
2. Remove handle insert screw.
3. Pull off the handle insert.
4. Pull of handle carriers.
5. Unscrew cartridge with 17mm
A/F spanner and replace if
necessary.
ENSURE PARTS ARE
REASSEMBLED IN THE
CORRECT SEQUENCE.
ENSURE PARTS ARE
REASSEMBLED IN THE
CORRECT SEQUENCE.