background image

ALTO ECOTHERM

A4740AA   Shower valve with wall bracket

A4741AA   Shower pack incl. three function kit and wall bracket

A5637AA   Shower valve with lever handle and wall bracket

A6385AA   Shower pack incl. three function kit with Cat 5 hose      

  

       retaining and wall bracket

IMPORTANT

BEFORE CONNECTION, FLUSH WATER 

THROUGH PIPEWORK TO REMOVE ALL 

DEBRIS ETC. WHICH COULD DAMAGE 

THE VALVE MECHANISM

Installation Instructions 

Thermostatic Bar Shower Valve

INSTALLER

After installation pass

to user for future reference

Содержание ALTO ECOTHERM A4740AA

Страница 1: ...andle and wall bracket A6385AA Shower pack incl three function kit with Cat 5 hose retaining and wall bracket IMPORTANT BEFORE CONNECTION FLUSH WATER THROUGH PIPEWORK TO REMOVE ALL DEBRIS ETC WHICH COULD DAMAGE THE VALVE MECHANISM Installation Instructions Thermostatic Bar Shower Valve INSTALLER After installation pass to user for future reference ...

Страница 2: ...2 150 304 78 105 G1 2 32 40 G3 4 150 297 78 105 G1 2 32 40 G3 4 Dimensions in millimetres may vary within permitted tolerances A4740AA A4741AA A6385AA A5637AA Fig 1 Fig 2 ...

Страница 3: ...7 THERMOSTATIC CARTRIDGE CALIBRATION 12 8 MAINTENANCE 12 9 COMMISSIONING PERIODIC CHECKS 13 10 FREQUENCY OF REGULAR SERVICING 13 11 THERMOSTATIC CARTRIDGE REPLACEMENT 14 A4740AA A4741AA A6385AA 11 THERMOSTATIC CARTRIDGE REPLACEMENT 15 A5637AA 12 FLOW CARTRIDGE REPLACEMENT 16 13 COLD WATER ISOLATION CWI TEST 17 14 CHECK VALVES REPLACEMENT 17 15 CLEANING 18 16 ISOLATING VALVES 18 17 SPARE PARTS 19 ...

Страница 4: ...rential is likely to exceed the 5 1 ratio See table 1 The minimum pressure for correct operation is 0 1 bar 1m head Pressure head is measured as the vertical distance between the bottom of the cold water storage tank which feeds the hot water system and the high est point on the shower spray plate When installing with a shower pump the use of a secondary tapping from the cylinder is highly recomme...

Страница 5: ...t that the water will become alternatively cold and hot To overcome this a 4 L min flow regulator should be fitted upstream of the thermostatic valve It should be fitted in any 15mm compression fitting in the dedicated cold supply pipe It is important to choose a compression fitting located in a position which is accessible after installation and it must be fitted the correct way round for the dir...

Страница 6: ... backflow risk for unrestrained hose zone of backflow risk for restrained hose w c spill over level shower tray or bath tub bidet w c spill over level restrained hose giving the 25 mm air gap is permitted 25mm minimum unrestrained hose would not be permitted hot and cold supplies to the thermostatic valve Alternatively single check valves can be fitted at the inlets and an additional check valve s...

Страница 7: ...t this stage Place wall plate over pipework and onto the wall surface A spirit level can be placed on the flats of the wall plate to ensure the level Once at the correct position the two fixing holes can be marked Drill two holes to suit appropri ate wall fixings 7 4 INSTALLATION GUIDE 2 IMPORTANT BEFORE CONNECTION FLUSH WATER THROUGH PIPEWORK TO REMOVE ALL DEBRIS ETC WHICH COULD DAMAGE THE VALVE ...

Страница 8: ...s should be trimmed level to the wall bracket If using a pipe cutter it will be necessary to mark the pipes and then remove the bracket before trimming to its correct length Note If the wall is to be subsequently tiled ensure there is sufficient movement in the duct pipework to allow the bracket to move forward by the thick ness of the tilling Cavity anchor plasterboard fixing 5 Use suitable wall ...

Страница 9: ... the slot at the bottom Shower outlet to underside Ensure the sealing washers are within the captive nuts of the shower valve Fit the shower valve to the wall bracket as shown Turn on the water supplies check for leaks Fit 15mm Olives x2 10 Use 30mm A F spanner CAUTION Take care not to damage chromed surfaces NOTE FOR IRELAND 15mm olives are supplied with this product Use olives if supply pipes ar...

Страница 10: ...ndle further downwards The handle will rotate a further 90 from the economy stop to the maximum flow Left handle controls water temperature This handle is shown above parked in the 40 C temperature stop position At this temperature stop position mixed water is delivered up to about 40 C To obtain cooler water rotate handle downwards To obtain higher water temperature press the left button and then...

Страница 11: ...er downwards The handle will rotate a further 90 from the economy stop to the maximum flow Left handle controls water temperature This handle is shown above parked in the 40 C temperature stop position At this temperature stop position mixed water is delivered up to about 40 C To obtain cooler water rotate handle downwards To obtain higher water temperature press the left button and then rotate th...

Страница 12: ...hanism d 3 Turn on the shower position a thermometer in the running water and when the temperature set tles rotate the temperature control mechanism un til 40ºC is achieved 4 Reconnect the handle carrier e ensuring the arrow guide c is at 12 o clock and refit the red U piece b 5 Reconnect the Handle The fitting of isolation valves and strainers is required as close as is practicable to the water s...

Страница 13: ...nd retested in accordance with the instructions detailed above The following procedures should be carried out after installation and every 12 months after to ensure that the valve is functioning correctly Check that 1 The application of the thermostatic valve matches the approved designation 2 The supply pressures are within the recommended range for the application 3 The supply temperatures are w...

Страница 14: ...dle 4 To remove the temperature handle carrier grey plastic moulding slide the black serrated lever clockwise and pull off This will expose the thermostatic cartridge 5 Unscrew cartridge with 24mm A F spanner and replace if necessary ENSURE PARTS ARE REASSEMBLED IN THE CORRECT SEQUENCE To clean the screens remove the o rings shown The screens will then slide off When clean replace the screens then...

Страница 15: ...w 3 Pull off the handle insert 4 To remove the temperature handle carrier grey plastic moulding slide the black serrated lever clockwise and pull off This will expose the thermostatic cartridge 5 Unscrew cartridge with 24mm A F spanner and replace if necessary ENSURE PARTS ARE REASSEMBLED IN THE CORRECT SEQUENCE To clean the screens remove the o rings shown The screens will then slide off When cle...

Страница 16: ... the flow control handle 4 Pull of handle carriers 5 Unscrew cartridge with 17mm A F spanner and replace if necessary 1 Unscrew dog point screw and pull off flow control handle 2 Remove handle insert screw 3 Pull off the handle insert 4 Pull of handle carriers 5 Unscrew cartridge with 17mm A F spanner and replace if necessary ENSURE PARTS ARE REASSEMBLED IN THE CORRECT SEQUENCE ENSURE PARTS ARE RE...

Страница 17: ...on 6 Remove temperature handle to check If this has been removed then the fail safe will not work Make sure the supply temperatures are within the ranges 55 to 65 C for hot 5 to 20 C for cold To perform a CWI test Turn the product on using the flow handle override the 50 economy flow stop on the handle rotate handle to max giving 100 flow The temperature handle button should be positioned at the f...

Страница 18: ... valve Both isolation valves strainers should be installed in an easily accessible location An in line combined isolating valve shown below can be purchased by contacting Customer Care Spares code E960613NU contains a pair of these valves This valve also contains a flow regulator and check valve which can be removed if not required 15 CLEANING When cleaning the shower valve always use soap based c...

Страница 19: ... A 963 427 NU 7 F 961 044 NU 8 A 962 230 NU 10 A 963 432 NU 11 A 963 400 NU 1 A 963 099 AA 4 A 962 998 NU 5 A 960 801 AA 6 A 963 427 NU 7 F 961 044 NU 8 A 962 230 NU Fig 5 Fig 6 10 A 861 312 NU 11 A 861 245 NU 11 A 963 400 NU 14 A 962 605 NU 15 A 961 810 NU 17 N 042 977 NU 19 A 962 595 NU 21 B 960 722 AA 24 B 960 721 NU 14 A 962 605 NU 15 A 961 810 NU 17 N 042 977 NU 19 A 962 595 NU 21 B 960 722 A...

Страница 20: ...INE 0870 129 6085 CUSTOMER CARE FAX 01482 499611 E MAIL UKcustcare idealstandard com Ideal Standard pursues a policy of continuing im provment in design and performance of its products This right is therefore reserved to vary specification without notice Ideal Standard is adivision of Ideal Standard UK Ltd Ideal Standard The Bathroom Works National Avenue Kingston upon Hull HU 4HS England ...