Chapter 3
Structured Cable Field Calibration and Testing
3-13
5.
To begin another Autotest, press AUTOTEST. If results from the current test have
not been saved, you will be prompted to discard or save the current test results
before the next Autotest will run.
Note: The tester also performs real time Analyze testing that enables you to
troubleshoot problem areas. If Autotest results indicate a failure, refer to the Analyze
Testing section for further details.
INTERPRETING AUTOTEST RESULTS
Pass/Fail Reporting
The overall Autotest result is displayed at the top right of the Autotest display screen.
Individual Autotest results are displayed to the right of each test.
Figure 3-2: Typical Overall Autotest Results Screen
Table 3-2: Test Result Symbols
Symbol
Overall Autotest Result
Overall test result is a pass if each individual test is a pass or a pass*.
Overall test result is a fail if one or more individual test is either a fail or a fail*.
Viewing Current Autotest Results
Results can be viewed at completion of the test sequence or saved for later viewing.
1.
Press the ARROW keys to highlight the desired test.
2.
Press ENTER to view test results.
Figure 3-3: Typical Individual Autotest Results Screen