Form Number TM61310
Rev 2 Aug 2007
Page 4
Me
Ac
(1)
asurement Characteristics
curacy is ±(% r number of digits) at 23°C ± 5°C, less than 80% R.H.
DC Volts
Range Resolution
Accuracy
Over voltage
protection
200.0mV 100
μ
V
2.000V 1mV
20.00V 10mV
200.0V 100mV
0.5% + 2
600V
1V
0.8% + 2
600V rms
Inp
(2)
ut Impedance:
10M
Ω
AC Volts
Range Resolution
Accuracy
Over voltage
protection
40-400Hz
200.0V 100mV
1.2% + 10
600V
1V
1.2% + 10
600V rms
Input Impedance:
4.5M
Ω
AC Conversion Type:
Average sensing rms indication calibrated to the sine wave in
put.
(3) DC Current
Resolution Accuracy
Overload
protection
Range
200.0 mA
25
se
0.1mA
1.5% + 2
0mA/250V
Fast Blow Fu
10.00A*
.01A
3.0% + 5
Not fused, 15 sec Max
*
Caution:
Do not make high current measurements on the 10A scale for longer that 15
ec
ds
s onds. This should be followed by a 15 minute cool down period. Exceeding 15 secon
may cause damage to the meter and/or the test leads.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
FAX 781.665.0780 - TestEquipmentDepot.com