10
Installation and Servicing
SECTION 1 - GENERAL
1.1 INTRODUCTION
The
i-mini C
range of boilers are wall mounted, full sequence,
automatic spark ignition, low water content, fanned flue, high
efficiency, condensing, combination gas boilers.
Note.
Due to the high efficiency of the boiler a plume of water
vapour will form at the terminal during operation.
Central heating (CH) output is fully modulating with a range of:
24
4.8 to 24.2kW
30
6.1 to 24.2kW
Instantaneous domestic hot water (DHW) output is also fully
modulating with a maximum of :
24 24.2kW
30 30.3kW
The boiler is supplied fully assembled with DHW plate heat
exchanger, diverter valve, circulating pump, pressure gauge,
safety valve and CH expansion vessel.
Variable CH and DHW temperature controls are fitted on the user
control and the boiler features a DHW preheat facility.
The boiler includes as standard:
-
Automatic bypass
-
Boiler frost protection
-
Daily pump and diverter valve exercise
The boiler casing is of white painted mild steel with a white
polymer front panel.
The boiler temperature controls are visible located in the control
panel on the front of the boiler.
The heat exchanger is manufactured from cast aluminium.
The boiler is suitable for connection to fully pumped, sealed
heating systems ONLY. Adequate arrangements for completely
draining the system by provision of drain cocks MUST be provided
in the installation pipework.
Pipework from the boiler is routed downwards.
Data Plate
The boiler model and serial number can be located on the bottom of the
boiler casing, shown in Frame 1 - Water & Gas Connection Diagram.
1.2 OPERATION
With no demand for CH, the boiler fires only when DHW is drawn
off, or periodically for a few seconds without any DHW draw-off, in
order to maintain the DHW calorifier in a heated condition. This
only occurs if pre-heat knob is in the ‘ON’ period.
When there is a demand for CH, the heating system is supplied at
the selected temperature of between 30
o
C and 80
o
C, until DHW
is drawn off. The full output from the boiler is then directed via
the diverter valve to the plate heat exchanger to supply a nominal
DHW draw-off of
24
9.9 l/min at 35
o
C temperature rise.
30
12.4 l/min at 35
o
C temperature rise.
The DHW draw off rate specified above is the nominal that the
boiler flow regulator will give. Due to system variations and
seasonal temperature fluctuations DHW flow rates/temperature
rise will vary, requiring adjustment at the draw off tap.
At low DHW draw-off rate the maximum temperature may exceed
65ºC.
The boiler features a comprehensive diagnostic system which
gives detailed information on the boiler status when operating,
and performance of key components to aid commissioning and
fault finding.
1.3 SAFE HANDLING
This boiler may require 2 or more operatives to move it to its
installation site, remove it from its packaging base and during
movement into its installation location. Manoeuvring the boiler
may include the use of a sack truck and involve lifting, pushing and
pulling.
Caution should be exercised during these operations.
Operatives should be knowledgeable in handling techniques when
performing these tasks and the following precautions should be
considered:
• Grip the boiler at the base.
• Be physically capable.
• Use personal protective equipment as appropriate, e.g. gloves,
safety footwear.
During all manoeuvres and handling actions, every attempt should
be made to ensure the following unless unavoidable and/or the
weight is light.
• Keep back straight.
• Avoid twisting at the waist.
• Avoid upper body/top heavy bending.
• Always grip with the palm of the hand.
• Use designated hand holds.
• Keep load as close to the body as possible.
• Always use assistance if required.
1.4 OPTIONAL EXTRA KITS
• Telescopic Horizontal Flue Terminal (1000mm long)
• Telescopic Horizontal Flue Terminal (600mm long)
• Telescopic Horizontal B Pack Flue (600mm long)
• Flue Extension Ducts (1000mm long)
• Flue Extension Ducts (2000mm long)
• Flue Extension Ducts (500mm long)
24-up to 9m
30-up to 8m
• 90
o
Elbow Kit (maximum per installation).
24-upto 6 elbows
30-upto 6 elbows
• 45
o
Elbow Kit (maximum per installation).
24-upto 6 elbows
30-upto 6 elbows
• Roof Flue Kit (inc. vertical connector) (to a maximum of 7.5m)
• Flue Finishing Kit
• High Level Flue Outlet Kit
• Balcony Flue Kit
• Soffit Flue Kit
• Adjustable Flue Support Bracket
• Flue Deflector Kit
• Raised Horizontal Flue Outlet Kit
• Concentric Flue Screw Retaining Kit
• Weather Collar
• Stand-Off Kit
• Condensate Pump Kit
• DHW Expansion Vessel Kit
• Weather Compensation Kit
• PRV Wall Outlet Kit
• Security Bracket Kit
• Mechanical Timer (24hr) Kit
Содержание i-mini C24
Страница 4: ...4 Installation and Servicing...
Страница 6: ...6 Installation and Servicing...
Страница 62: ...62 Installation and Servicing SECTION 5 SPARE PARTS...
Страница 68: ...68 NOTES Installation and Servicing...
Страница 69: ...69 NOTES Installation and Servicing...
Страница 70: ...70 NOTES Installation and Servicing...
Страница 71: ...71 NOTES Installation and Servicing...