Ideal Heating EVOMAX 2 40 Скачать руководство пользователя страница 5

5

IMAX XTRA 2 - 

Flue Damper Kit Instructions

INSTRUCTIONS

Gnd 

OT 

Open 

Therm 

 

Gnd

In 

Out 

LV 

External 

Interlock 

Room 

Stat 3 

QAA55 

CL- 

Room 

Stat 2 

QAA55 

CL- 

Room 

Stat 1 

QAA55 

CL- 

Gnd 

0-10 

0-10V 

Input 

Outside 

Sensor 

DHW 

Sensor 

Header 

Sensor 

Fused Spur 

Mains 

In 

 

 

 

Out  In 

In 

Out 

Switched 

Live 2 

Switched 

Live 1 

Boiler Pump 

or 

System Pump 

COM 

NO

 

NO

 

COM 

Volt Free 

Fault 

Relay 

Volt Free 

Burner 

Relay  

In 

Out 

230V 

External 

Interlock 

Flue 

Damper

External System 

Controls

N

N

N

N

DHW Pump or 

Hea�ng 

Circuit 2 Pump 

Hea�ng 

Circuit 1

Pump 

6A 

12A  12B 

11 

10A  10B  10C 

9A 

9B 

9C 

9D 

6B 

4A 

4B 

2A 

2B 

PWM

 

PWM

Pump

M

The schematic below shows the wiring for the Flue Damper.

Turn on the power to the boiler and recommission the boiler to configure the connected motorised flue damper.

Power from main supply 

MUST be the same phase 

as the boiler supply.

Note: 

If you are adding a Motorised Flue Damper to an Imax Xtra 2 that already has a Boiler Pump controlled directly from the 

boiler you must observe the following:

• 

The On/Off Controlled Boiler Pump MUST be converted to Modulation Controlled Boiler Pump.

• 

If the Boiler pump has a PWM Modulation Input available you can use the schematic shown in Figure 3.

• 

If the Boiler pump only has a 0-10V Modulation Input available you need to order the 0-10V Pump Kit. The schematic   

  showing the wiring is shown in the instructions which are provided with the kit.

Fig. 2

Gnd

In 

Out 

LV 

External 

Interlock 

Boiler

Pump

12A  12B 

PWM

 

PWM

Pump

Fig. 3

Содержание EVOMAX 2 40

Страница 1: ...ditioned or copy parts that have not been clearly authorised by Ideal Heating For the very latest copy of literature for specification and maintenance practices visit our website idealheating com where you can download the relevant information in PDF format FLUE DAMPER KIT INSTALLATION IMAX XTRA 2 80 120 160 200 240 280 80P 120P 160P 200P 240P October 2021 UIN 230511 A01 ...

Страница 2: ...arts 1 Motorised flue damper Shown in Fig 1 1 2 FLUE DAMPER KIT PARTS 1 3 INSTALLING THE MOTORISED FLUE DAMPER INTO THE FLUE Fig 1 The motorised flue damper has a chamfer on the male end for inserting into a flue piece and a lip seal on the female end to receive another section of flue Note The 150mm diameter motorised flue damper is for use with 80kW 120kW and 160kW Imax Xtra 2 boilers The 200mm ...

Страница 3: ...the wiring to the flue damper PCB as follows 1 Thread the five wires though the cable grommet located on the Flue Damper Control box 2 Connect the Live wire to Pin 1 of the screw terminal of the flue damper PCB 3 Connect the Neutral wire to Pin 2 of the screw terminal of the flue damper PCB 4 Connect the Earth wire to the earthing point of the Flue Damper 5 Connect the Flue Damper Signal wire to P...

Страница 4: ... connector I3_CN from Installation Connection I3 2 Connect the Live wire to Pin 3 of connector I3_CN 3 Connect the Neutral wire to Pin 2 of connector I3_CN 4 Connect the Earth wire to Pin 1 of connector I3_CN 5 Push connector I3_CN back into Installation Connection I3 6 Remove connector I12_CN_B from Installation Connection I12 7 Connect the Flue Damper Signal wire to Pin 1 of connector I12_CN_B 8...

Страница 5: ...the wiring for the Flue Damper Turn on the power to the boiler and recommission the boiler to configure the connected motorised flue damper Power from main supply MUST be the same phase as the boiler supply Note If you are adding a Motorised Flue Damper to an Imax Xtra 2 that already has a Boiler Pump controlled directly from the boiler you must observe the following The On Off Controlled Boiler P...

Страница 6: ...tion If you are installing an electrically operated flue damper onto a boiler that does not require boiler pump control then you can select No Boiler Pump This is done at the Boiler Pump page shown by selecting the No Boiler Pump option For either of the selections above you can now configure the Flue Damper This is done at the Cascade Flue with Electronic Damper Control page shown by selecting th...

Страница 7: ...7 IMAX XTRA 2 Flue Damper Kit Instructions INSTRUCTIONS ...

Страница 8: ...er an ISO 9001 registered quality management system FM 59915 At Ideal Heating we take our environmental impact seriously therefore when installing any Ideal Heating product please make sure to dispose of any previous appliance in an environmentally conscious manner Households can contact their local authority to find out how See https www gov uk managing your waste an overview for guidance on how ...

Отзывы: