Response 80 / 100 / 120 - 

User's

Check that the overheat thermostat has not tripped -
press button (H) to reset.

If these simple checks fail to solve the problem, or the
problem recurs, consult your service engineer.

B

Hot water but no heating

Check that the programmer and room thermostat (if fitted)
are both calling for heat.

If the boiler has been switched off 

completely

 for some

time the pump may have stuck (if hot water is in use this
should 

not

 happen as the pump runs for 5 seconds at the

end of each hot water draw-off). A sharp tap on the metal
body of the pump may free it.

If these simple checks fail to solve the problem, or the problem
recurs,  consult your service engineer.

C. Heating but no hot water

Check that 

cold

 water does flow out of the hot taps at a

minimum rate of 3.5 litres per minute (or 1 pint in 10
seconds or less).

If not, look for stop valves not fully open.

If these simple checks fail to solve the problem, or the problem
recurs,  consult your service engineer.

D.

Hot water temperature incorrect

If the supply of hot water from the appliance is incorrect
with the domestic hot water tap fully open then the
Response boiler includes a domestic hot water restrictor
handle for you to adjust the water flow rate to obtain the
temperature you require. The restrictor handle is located
beneath the boiler on the left.

BOILER CONTROLS

To shut down the boiler

Set the mains switch (C) to OFF.

When heating is again required, restore the switch to the ON
position.

WARNING.

If no frost protection is provided and frost is likely during a short
absence from home, leave the heating controls (or control (F) )
at a reduced temperature setting.

For longer periods, the entire system should be drained -
including the domestic water supply .

If the system includes a frost thermostat then, during cold
weather, the boiler should be turned OFF by selecting the OFF
programme at the time control.

The mains supply should be left switched ON.

If in doubt, ask your installer.

To relight the boiler

Repeat the procedure detailed in 'To light the boiler'.

Faults

A. No heating or hot water

Check that gas and electricity are available at the boiler and
that all switches are on.

Check that the system water pressure gauge (G) reads 

at

least 0.5 bar

.

Rotate the restrictor handle anti-clockwise
to increase temperature and clockwise to
decrease temperature as indicated on the
handle.

LEGEND

A

'Mains on' neon

B

'Burner on' neon

C

Mains switch

D

Heating switch

E

Programmer (optional)

F

Radiator temperature
control

G

System water pressure
gauge

H

Overheat thermostat reset

Note.

Small movements of the handle will only be necessary
to effect the water temperature change required.

If these simple checks fail to solve the problem, or the
problem recurs,  consult your service engineer.

Содержание Response 100

Страница 1: ...Supplied By www heating spares co Tel 0161 620 6677 ...

Страница 2: ... is fitted and it fits inside a cupboard Its compact size up to half that of other combis makes the Response ideal for any kitchen It can be installed inside a standard size kitchen wall unit without insulation and with minimal ventilation Response The combi you can rely on The Response has been designed and developed with reliability as the number one priority But even the finest engineered produ...

Страница 3: ...ppliance No 47 348 02 Natural Gas Models Only CAUTION To avoid the possibility of injury during the installation servicing or cleaning of this appliance care should be taken when handling edges of sheet steel components Response 100 G C Appliance No 47 348 04 Response 120 G C Appliance No 47 348 01 ...

Страница 4: ...damp cloth and mild detergent DO NOT use abrasive cleaning materials Maintenance The appliance should be serviced at least once a year by a CORGI registered installer IMPORTANT DRAINING THE SYSTEM It is not good practice to drain off radiators to decorate behind them In the case of sealed system boilers such as this Response this will lower the system pressure AND MAY CAUSE THE BOILER TO STOP WORK...

Страница 5: ...ure you require The restrictor handle is located beneath the boiler on the left BOILER CONTROLS To shut down the boiler Set the mains switch C to OFF When heating is again required restore the switch to the ON position WARNING If no frost protection is provided and frost is likely during a short absence from home leave the heating controls or control F at a reduced temperature setting For longer p...

Страница 6: ...5 4JN Telephone 01482 492 251 Fax 01482 448 858 Registration No London 322 137 The code of practice for the installation commissioning servicing of central heating systems Caradon Plumbing Limited is a member of the Benchmark initiative and fully supports the aims of the programme Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in...

Страница 7: ...oilers and our service We ll be giving away a free boiler for the five best ideas every year to be selected by our Technical Director Please complete this form using extra sheets if required and post it or fax it to us on 01482 498699 Boiler details Model Size e g Classic RS 230 Mexico CF 3 60 etc Details on control panel door Date of Installation Installer details Name Address Post Code Telephone...

Страница 8: ...s and installer s introduction to the Ideal domestic boiler range The Ideal Householders Guide to assist the installer when presenting to his her customers Technical manuals required The Ideal C class combi boiler The Ideal Classic wall hung boiler The Ideal Classic System wall hung boiler The Ideal Classic LX Deluxe wall hung boiler The Ideal Mexico floor standing boiler The Ideal Minimiser heat ...

Отзывы: