Logic Combi ES - 

User’s

minimum Clearances

Clearances of 

165mm (6 

1/2

) above, 

100mm (4”

) below, 

2.5mm (1/8”

) at the sides and 

450mm (17 3/4

”) at the front of 

the boiler casing must be allowed for servicing.

Bottom clearance

Bottom clearance after installation can be reduced to 5mm. 
This must be obtained with an easily removable panel, to 

enable the consumer to view the system pressure gauge, and 

to provide the 100mm clearance required for servicing.

To light the boiler. refer to Frame 1

If a programmer is fitted  refer to separate instructions for the 

programmer before continuing.

1.

  CHECK THAT THE ELECTRICITY SUPPLY TO BOILER IS 

OFF.

2.

  Set the mains mode knob control (D) to ‘Off’.

3. 

Set the Domestic Hot Water temperature control (B) and 

Central Heating temperature control (C) to ‘max’.

4.

  Ensure that all hot water taps are turned off.

5.

  Switch ON electricity to the boiler and check that all 

external controls, e.g. programmer and room thermostat, 

are ON.

6.

  Set the mode knob control to winter (   ).

The boiler will commence the ignition sequence, supplying 

heat the central heating, if required.

Note. In normal operation the boiler status display (E) will 

show  codes:

 Standby - no demand for heat.      

 CH being supplied.

 DHW being supplied.                     

  During normal operation the burner on indicator (F) will 

remain illuminated when the burner is lit.

Note:  If the boiler fails to light after five attempts the fault code 

 will be displayed.

REsET pROCEDURE

To reset boiler, turn the mode control knob (D) to reset position 

and immediately turn knob back to required setting.  The boiler 

will repeat the ignition sequence.  If the boiler still fails to light 

consult a Gas Safe Registered Engineer or in IE a Registered 

Gas Installer (RGII).

Introduction

The 

Logic Combi Es 

is a wall mounted, room sealed, condensing 

combination boiler, featuring full sequence automatic spark ignition 

and fan assisted combustion.
Due to the high efficiency of the boiler, condensate is produced from 

the flue gases and this is drained to a suitable disposal point through 

a plastic waste pipe at the base of the boiler.  A condensate ‘plume’ 

will also be visible at the flue terminal.
The 

Logic Combi Es 

is a combination boiler providing both central 

heating and instantaneous domestic hot water.

safety

Current gas safety (installation & Use) 

regulations or rules in force.

In your own interest, and that of safety, it is the law that this boiler 

must be installed by a Gas Safe Registered Engineer, in accordance 

with the above regulations.
In IE, the installation must be carried out by a Registered Gas Installer 

(RGII) and installed in accordance with the current edition of I.S. 813 

“Domestic Gas Installations”, the current Building Regulations and 

reference should be made to the current ETCI rules for electrical 

installation.

It is essential that the instructions in this booklet are strictly followed, 
for safe and economical operation of the boiler.

Electricity supply

This appliance must be earthed.

supply: 230 V ~ 50 hz. The fusing should be 3a.

important notes

  This appliance must not be operated without the casing correctly 

fitted and forming an adequate seal.

  If the boiler is installed in a compartment then the compartment 

MUST NOT be used for storage purposes.

  If it is known or suspected that a fault exists on the boiler then 

it MUST NOT BE USED until the fault has been corrected by a 

Gas Safe Registered Engineer or in IE a Registered Gas Installer 

(RGII).

 

Under NO circumstances should any of the sealed components on 

this appliance be used incorrectly or tampered with.

  This appliance is not intended for use by persons (including 

children) with reduced physical, sensory or mental capabilities, or 

lack of experience and knowledge, unless they have been given 

supervision or instructions concerning use of the appliance by a 

person responsible for their safety.

  Children should be supervised to ensure that they do not play with 

the appliance.

In cases of repeated or continuous shutdown a Gas Safe Registered 

Engineer or in IE a Registered Gas Installer (RGII) should be called 

to investigate and rectify the condition causing this and carry out an 

operational test. Only the manufacturers original parts should be used 

for replacement.

ThE BENChMaRK sERVICE INTERVaL RECORD MUsT BE COMpLETED aFTER EaCh sERVICE

Ideal stelrad group

 is a member of the Benchmark scheme and fully supports the aims of 

the programme.  Benchmark has been introduced to improve the standards of installation and 

commissioning of central heating systems in the UK and to encourage the regular servicing of all 

central heating systems to ensure safety and efficiency.

All Gas Safe Register installers carry a Gas Safe Register ID card, and have a registration number.  Both should be recorded in the

Benchmark Commissioning Checklist.  You can check your installer by calling Gas Safe Register direct on 0800 4085500.

FOR aNy qUERIEs pLEasE RINg ThE

IDEaL CONsUMER hELpLINE : 01482 498660

NOTE. BOILER REsET pROCEDURE - 

To reset boiler, turn mode control knob to reset position and immediately turn knob back to required setting.

Содержание LOGIC Combi ES24

Страница 1: ...art on this appliance use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not been clearly authorised by Ideal For installation guide see reverse of book ...

Страница 2: ...neer in accordance with the above regulations In IE the installation must be carried out by a Registered Gas Installer RGII and installed in accordance with the current edition of I S 813 Domestic Gas Installations the current Building Regulations and reference should be made to the current ETCI rules for electrical installation It is essential that the instructions in this booklet are strictly fo...

Страница 3: ...ler which is most efficient when operating in condensing mode The boiler will operate in this mode if the CH temperature control C is set to the e position economy mode This control should be set to maximum for very cold periods To shut down the boiler Set the mode knob control to OFF To relight the boiler Repeat the procedure detailed in To light the boiler Frost protection If no system frost pro...

Страница 4: ...ther localised hazards 4 Once the blockage is removed and the condensate can flow freely reset the appliance Refer to To Light the boiler 5 If the appliance fails to ignite call your Gas Safe Registered engineer Preventative solutions During cold weather set the boiler stat to maximum Must return to original setting once cold spell is over Place the heating on continuous and turn the room stat dow...

Страница 5: ...entral heating Check the time settings on the programmer are as you require and adjust if necessary Check the programmer internal or external to the boiler is in an ON position and the room thermostat is turned up NO HOT WATER OR CENTRAL HEATING Check the fused spur is turned on and ensure switch mode control knob D is in the winter position See boiler Operation Modes and Fault Codes section Does ...

Страница 6: ...s a call for central heating but the appliance has reached the desired temperature set on the boiler The boiler has a call for hot water but the appliance has reached the desired temperature set on the boiler The boiler is operating in central heating mode The boiler is operating in hot water mode The boiler is operating in frost mode continued OPERATION MODES ...

Страница 7: ...RIPTION Low Water Pressure ACTION Check system pressure is between 1 1 5bar on the pressure gauge If the boiler fails to operate then please contact Ideal if under warranty or alternatively a Gas Safe Registered Engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII Flame Loss 1 Check other gas appliances in the house are working to confirm a supply is present in ...

Страница 8: ...1482 448858 Registration No London 322 137 Ideal Stelrad Group pursues a policy of continuing improvement in the design and performance of its products The right is therefore reserved to vary specification without notice Ideal Consumer Helpline Tel 01482 498660 www idealheating com ...

Отзывы: