6.  POINTS FOR THE BOILER USER

Note.

  

In line with our current warranty policy we would ask that you check through the following guide to identify any 

problems external to the boiler prior to requesting a service engineer’s visit.  Should the problem be found to be other 

than with the appliance we reserve the right to levy a charge for the visit, or for any pre-arranged visit where access is not 

gained by the engineer.

TROUBLESHOOTING

YES

YES

NO HOT WATER

Check the mains power is turned 

on and ensure mode knob (C) is 

in the summer or winter position

Is water coming out of the hot 

water tap when turned on?

NO CENTRAL HEATING

Check the mains power is turned 

on and ensure mode knob (C) is 

in the winter position

Does the boiler operate and 

provide central heating?

Check the time settings on the 

programmer are as you require 

and adjust if necessary

Check the programmer (internal 

or external to the boiler) is in 

an “ON” position and the room 

thermostat is turned up

NO HOT WATER OR 

CENTRAL HEATING

Check the mains power is turned 

on and ensure mode knob (C) is 

in the winter position

See boiler “Operation Modes” 

and “Fault Codes” section

Does the boiler have a display 

showing on the front control 

panel?

See boiler “Fault Codes” 

section.  If ‘

00

’ is displayed then 

contact Ideal Customer Services 

Helpline if your appliance is 

under warranty or a Gas Safe 

Registered Engineer, in IE a 

Registered Gas Installer (RGII), 

if out of warranty

YES

NO

Contact a Gas Safe Registered 

Engineer or in IE a Registered 

Gas Installer (RGII)

NO

See boiler “Operation Modes” 

and “Fault Codes” section.

If ‘

00

’ is displayed then contact a 

Gas Safe Registered Engineer 

or in IE a Registered Gas 

Installer (RGII)

NO

Contact a Gas Safe Registered 

Engineer or in IE a Registered 

Gas Installer (RGII)

Содержание LOGIC COMBI C24IE

Страница 1: ...uire Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Boilers For the very latest copy of literature for specification and maintenance practices visit our website...

Страница 2: ...les for electrical installation It is essential that the instructions in this booklet are strictly followed for safe and economical operation of the boiler ELECTRICITY SUPPLY This appliance must be ea...

Страница 3: ...frost protection see Frost Protection PREHEAT DOMESTIC HOT WATER The domestic hot water heat exchanger within the boiler can be kept preheated to provide faster delivery of hot water at the tap This i...

Страница 4: ...rds the MAX position to meet heating requirements This will depend on the house and radiators used Reducing the room thermostat setting by 1 C can reduce gas consumption by up to 10 WEATHER COMPENSATI...

Страница 5: ...when using warm water as this may freeze and cause other localised hazards 4 Once the blockage is removed and the condensate can flow freely restart the appliance Refer to To Start the boiler 5 If th...

Страница 6: ...e time settings on the programmer are as you require and adjust if necessary Check the programmer internal or external to the boiler is in an ON position and the room thermostat is turned up NO HOT WA...

Страница 7: ...heating mode The boiler is operating in domestic hot water preheat mode The boiler is operating in domestic hot water mode The boiler is operating in frost protection 7 NORMAL OPERATION DISPLAY CODES...

Страница 8: ...ent in the property 2 If other appliances do not work or there are no other appliances check the gas supply is on at the meter and or pre payment meter has credit If the boiler fails to operate then p...

Отзывы: