30
INSTALLATION
icos system -
Installation and Servicing
35 FUNCTIONAL FLOW WIRING DIAGRAM
WARNING.
Whilst effecting the required gas soundness test and purging air from the gas
installation, open all windows and doors, extinguish naked lights and
DO NOT SMOKE.
A. Electrical Installation
1.
Checks to ensure electrical safety should be carried out by
a competent person.
2.
ALWAYS carry out the preliminary electrical system
checks, i.e. earth continuity, polarity, resistance to earth
and short circuit, using a suitable test meter.
B. Gas Installation
1.
The whole of the gas installation, including the meter,
should be inspected and tested for soundness and purged
in accordance with the recommendations of BS. 6891.
In IE refer to I.S.813:2002.
2.
Purge air from the gas installation by the approved
methods only.
36 COMMISSIONING AND TESTING
Dry fire thermistor
nm8
0
4
3
LEGEND
b -
blue
bk -
black
br -
brown
gy -
grey
or -
orange
pk -
pink
r
-
red
v -
violet
w -
white
y -
yellow
y/g -
yellow/green
INST
ALLA
TION
200214-11.pmd