2
Classic SE Propane FF -
Users
Minimum clearances
A clearance of 533mm (21") MUST be available at the front of the
boiler for servicing.
The minimum clearances given below MUST be complied with in
order to maintain the safe running of the boiler and to facilitate
servicing.
Above the boiler
100 mm
(4")
At each side of the boiler
5 mm
(
1/4
")
Underneath the boiler
100 mm
(4")
In front of the boiler
450 mm
(17
3 /4
")
To light the boiler.
Refer to Frame 1
1. CHECK THAT THE ELECTRICITY SUPPLY TO THE BOILER
IS OFF.
2. Open the controls access door by hinging downwards.
3. Ensure that the gas service cock (D) is OPEN.
4. Press the overheat reset button (E), located as shown in
Frame 1.
5. Ensure that the mains on/off switch (C) is in the OFF
position.
6. Switch ON the electricity supply to the boiler. Check that all
external controls, e.g. room thermostat etc., are ON.
7. Turn the boiler thermostat knob (B) to position 6 and the
mains on/off switch (C) to ON. After about 15 seconds the
boiler will light automatically - this can be viewed through the
sight glass (A).
Set the boiler thermostat to the desired position.
8. Close the controls access door.
In winter conditions, i.e. central heating and domestic hot water,
the thermostat should be set at position 5 or 6.
For summer conditions, i.e. domestic hot water only, the
thermostat should be set at position 3.
These settings, however, are offered for general guidance only
and other settings may be found preferable, dependent upon the
type of system installed or as recommended by the installer.
Approximate flow temperatures for the boiler thermostat settings are:
CLASSIC SE FF
(
Propane Gas Models Only)
Introduction
It is essential that the instructions in this booklet are strictly
followed, for safe and economical operation of the boiler.
Gas Safety (Installation & Use)
Regulations or rules in force.
In your own interest, and that of safety, it is the law that this
boiler must be installed by a CORGI registered installer or in
IE a competent person, in accordance with the above
regulations.
Electricity Supply
This appliance must be efficiently earthed.
Supply: 230 V ~ 50 Hz. The fusing should be 3A.
Connection must be made in a way that allows complete
isolation of the electrical supply such as a double pole switch
having a 3mm (1/8") contact separation in both poles, or a plug
and socket, serving only the boiler and system controls. The
means of isolation must be accessible to the user after
installation.
Important notes
a.
This appliance must not be operated without the casing
correctly fitted and forming an adequate seal.
b.
If the boiler is installed in a compartment then the
compartment MUST NOT be used for storage purposes.
c.
The ventilation provided for the boiler during installation
MUST NOT be blocked, and a check should be made
periodically that the ventilation areas are free from any
obstruction.
d.
If it is known or suspected that a fault exists on the boiler
then it MUST NOT be used until the fault has been
corrected by a CORGI registered installer or in IE a
competent person.
e.
Inflammable materials must not be placed in close
proximity to the appliance. Materials giving off flammable
vapours must not be stored in the same room as the
appliance.
f.
Under NO circumstances should any of the sealed
components on this appliance be used incorrectly or
tampered with.
g. Where the boiler is fitted with a Vertex Flue System with a
draught diverter in the loft, the loft space MUST NOT be
used as a dwelling area.
To shut down the boiler
1. For short periods: Turn the boiler on/off switch (C) to OFF.
When heating is again required, restore the switch to ON.
2. For longer periods: Turn the boiler on/off switch (C) to OFF.
Switch the electricity supply to OFF.
Frost protection
If no frost protection is provided and frost is likely during a short
absence from home, leave the heating controls at a reduced
temperature setting.
For longer periods, the entire system should be drained - including
the domestic water supply. If the system includes a frost thermostat
then, during cold weather, the boiler should be turned OFF at the
time switch(es) ONLY. The mains supply should be left switched
ON, with the boiler thermostat left in the normal running position.
Models G.C. Appliance No.
White
Classic SE15P FF ....... 41 395 37
Classic SE18P FF ....... 41 395 38
Classic SE24P FF ....... 41 395 39
Silver
Classic SE15P FF ....... 41-397-72
Classic SE18P FF ....... 41-397-73
Classic SE24P FF ....... 41-397-74
Knob Setting
Flow Temperature
°C
°F
1
56
133
2
61
142
3
66
152
4
72
161
5
77
170
6
82
180
CAUTION. To avoid the possibility of injury during the installation, servicing or cleaning
of this appliance care should be taken when handling edges of sheet steel components