background image

2

 Classic SE Propane FF - 

Users

Minimum clearances

A clearance of 533mm (21") MUST be available at the front of the
boiler for servicing.

The minimum clearances given below MUST be complied with in
order to maintain the safe running of the boiler and to facilitate
servicing.

Above the boiler

100 mm

(4")

At each side of the boiler

5 mm

(

1/4

")

Underneath the boiler

100 mm

(4")

In front of the boiler

450 mm

(17 

3 /4

 ")

To light the boiler.

Refer to Frame 1

1. CHECK THAT THE ELECTRICITY SUPPLY TO THE BOILER

IS OFF.

2. Open the controls access door by hinging downwards.

3. Ensure that the gas service cock (D) is OPEN.

4. Press the overheat reset button (E), located as shown in

Frame 1.

5. Ensure that the mains on/off switch (C) is in the OFF

position.

6. Switch ON the electricity supply to the boiler. Check that all

external controls, e.g. room thermostat etc., are ON.

7. Turn the boiler thermostat knob (B) to position 6 and the

mains on/off switch (C) to ON.  After about 15 seconds the
boiler will light automatically - this can be viewed through the
sight glass (A).
Set the boiler thermostat to the desired position.

8. Close the controls access door.

In winter conditions, i.e. central heating and domestic hot water,
the thermostat should be set at position 5 or 6.

For summer conditions, i.e. domestic hot water only, the
thermostat should be set at position 3.

These settings, however, are offered for general guidance only
and other settings may be found preferable, dependent upon the
type of system installed or as recommended by the installer.

Approximate flow temperatures for the boiler thermostat settings are:

CLASSIC SE FF

 

(

Propane Gas Models Only)

Introduction

It is essential that the instructions in this booklet are strictly
followed, for safe and economical operation of the boiler.

Gas Safety (Installation & Use)
Regulations or rules in force.

In your own interest, and that of safety, it is the law that this
boiler must be installed by a CORGI registered installer or in
IE a competent person, in accordance with the above
regulations.

Electricity Supply

This appliance must be efficiently earthed.

Supply: 230 V ~ 50 Hz. The fusing should be 3A.

Connection must be made in a way that allows complete
isolation of the electrical supply such as a double pole switch
having a 3mm (1/8") contact separation in both poles, or a plug
and socket, serving only the boiler and system controls. The
means of isolation must be accessible to the user after
installation.

Important notes

a.

This appliance must not be operated without the casing
correctly fitted and forming an adequate seal.

b.

If the boiler is installed in a compartment then the
compartment MUST NOT be used for storage purposes.

c.

The ventilation provided for the boiler during installation
MUST NOT be blocked, and a check should be made
periodically that the ventilation areas are free from any
obstruction.

d.

If it is known or suspected that a fault exists on the boiler
then it MUST NOT be used until the fault has been
corrected by a CORGI registered installer or in IE a
competent person.

e.

Inflammable materials must not be placed in close
proximity to the appliance.  Materials giving off flammable
vapours must not be stored in the same room as the
appliance.

f.

Under NO circumstances should any of the sealed
components on this appliance be used incorrectly or
tampered with.

g. Where the boiler is fitted with a Vertex Flue System with a

draught diverter in the loft, the loft space MUST NOT be
used as a dwelling area.

To shut down the boiler

1. For short periods:   Turn the boiler on/off switch (C) to OFF.

When heating is again required, restore the switch to ON.

2. For longer periods:  Turn the boiler on/off switch (C) to OFF.

Switch the electricity supply to OFF.

Frost protection

If no frost protection is provided and frost is likely during a short
absence from home, leave the heating controls at a reduced
temperature setting.

For longer periods, the entire system should be drained -  including
the domestic water supply.  If the system includes a frost thermostat
then, during cold weather,  the boiler should be turned OFF at the
time switch(es) ONLY. The mains supply should be left switched
ON, with the boiler thermostat left in the normal running position.

Models                     G.C. Appliance No.

White
Classic SE15P FF ....... 41 395 37
Classic SE18P FF ....... 41 395 38
Classic SE24P FF ....... 41 395 39

Silver
Classic SE15P FF ....... 41-397-72
Classic SE18P FF ....... 41-397-73
Classic SE24P FF ....... 41-397-74

Knob Setting

Flow Temperature

°C

°F

1

56

133

2

61

142

3

66

152

4

72

161

5

77

170

6

82

180

CAUTION.  To avoid the possibility of injury during the installation, servicing or cleaning
of this appliance care should be taken when handling edges of sheet steel components

Содержание CLASSIC SE FF

Страница 1: ...iance use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Boilers Classic Your Ideal users guide See reverse for Classic installation servicing instructions ...

Страница 2: ...le switch having a 3mm 1 8 contact separation in both poles or a plug and socket serving only the boiler and system controls The means of isolation must be accessible to the user after installation Important notes a This appliance must not be operated without the casing correctly fitted and forming an adequate seal b If the boiler is installed in a compartment then the compartment MUST NOT be used...

Страница 3: ...the aims of the programme Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency Changing gas cylinders a Ensure that the replacement gas cylinder is the correct one for the installation b Extinguish any fire flame or source of...

Страница 4: ...l heating or hot water Check on off switch C is in the on position Press overheat thermostat E the boiler should then relight If the fault recurs turn off the boiler and contact the installer Boiler goes through the ignition sequence but will not fire for central heating or hot water Check gas supply try at another gas appliance e g cooker fire If no gas supply then not a boiler fault contact your...

Отзывы: