Supplied By www.heating spares.co Tel. 0161 620 6677
3
Classic LXFF & FF -
User's
CLASSIC LX FF & FF
(
Natural Gas Models Only)
Minimum clearances
A clearance of 533mm (21") MUST be available at the front of the
boiler for servicing.
The minimum clearances given below MUST be complied with
in order to maintain the safe running of the boiler and to
facilitate servicing.
Above the boiler
100 mm
(4")
At each side of the boiler
5 mm
(
1/4
")
Underneath the boiler
100 mm
(4")
In front of the boiler
450 mm
(17
3 /4
")
Introduction
It is essential that the instructions in this booklet are
strictly followed, for safe and economic operation of
the boiler.
Gas safety (Installation & Use) Regulations 1994,
amendments 1996 or rules in force.
In your own interest, and that of safety, it is the law that this
boiler must be installed by a registered installer, in accordance
with all national and local regulations.
Electricity Supply
This appliance must be efficiently earthed.
Supply: 230 V ~ 50 Hz.
The fusing should be 3A.
Connection must be made in a way that allows complete
isolation of the electrical supply such as a double pole
switch having a 3mm (1/8") contact separation in both
poles, or a plug and socket, serving only the boiler and
system controls. The means of isolation must be
accessible to the user after installation.
Important notes
a.
This appliance must not be operated without the casing
correctly fitted and forming an adequate seal.
b.
If the boiler is installed in a compartment then the
compartment MUST NOT be used for storage purposes.
c.
The ventilation provided for the boiler during installation
MUST NOT be blocked, and a check should be made
periodically that the ventilation areas are free from any
obstruction.
d.
If it is known or suspected that a fault exists on the boiler
then it MUST NOT be used until the fault has been corrected
by a CORGI registered installer.
e.
Inflammable materials must not be placed in close proximity
to the appliance. Materials giving off flammable vapours
must not be stored in the same room as the appliance.
f.
Under NO circumstances should any of the sealed
components on this appliance be used incorrectly or
tampered with.
CAUTION.
To avoid the possibility of injury during the installation, servicing or cleaning of
this appliance care should be taken when handling edges of sheet steel components
Standard
Deluxe
Classic
FF 230 ....................... G.C. No. 41 387 01
Classic
FF 240 ....................... G.C. No. 41 387 02
Classic
FF 250 ....................... G.C. No. 41 387 03
Classic
FF 260 ....................... G.C. No. 41 387 04
Classic
FF 270 ....................... G.C. No. 41 387 05
Classic
FF 280 ....................... G.C. No. 41 387 06
Classic FF 2 100 ...................... G.C. No. 41 349 71
Classic
LXFF 230 ..................... G.C. No. 41 387 24
Classic
LXFF 240 ..................... G.C. No. 41 387 25
Classic
LXFF 250 ..................... G.C. No. 41 387 26
Classic
LXFF 260 ..................... G.C. No. 41 387 27
Classic
LXFF 270 ..................... G.C. No. 41 387 28
Classic
LXFF 280 ..................... G.C. No. 41 387 29