Buccaneer GTE - 

User's

1

BOILER CONTROLS / DISPLAY

1 Boiler on/off switch

Position

..... ON

Position 

..... OFF

2. Alarm light

Comes on when the burner is in safety
lockout

3. Summer/Winter switch

W i n t e r

Start the heating pump

Summer

The heating pump stops
12 minutes after the
changeover to summer
mode.

4. Test-STB button

When held in the pressed position it tests the
safety thermostat and cuts off the pump(s)

5. Safety thermostat (with manual reset)

  Set

to 110

0

C

6. Timed circuit breaker (4A)

7. Electronic thermostat

Adjustment of the boiler flow temperature

8. Light on

Indicates the display above it is showing the
boiler flow temperature

DOMESTIC HOT WATER
(combination boilers or those fitted with a DHW sensor)
Items 9 & 10 only.
9. Light on

Indicates the display above it is showing the DHW temperature.

10. Electronic thermostat

Adjustment of the average DHW storage temperature

Notes for items 9 & 10 only.

Combination boilers or those fitted with a DHW sensor.

 When the system

is switched on it performs an air elimination sequence of the hot water
calorifier lasting for 1 minute, by intermittently operating the DHW load
pump and the CH pump.  This air elimination sequence is de-activated if
the calorifier temperature is more than 25

0

C

Summer/Winter Switch

If DHW has been in demand, a delay of approx. 1

minute will occur for the change from the DHW pump to the CH pump, after
the changeover to Winter mode.

 Boiler flow

3

DISPLAY FEATURES

Central Heating only

The green Heating LED illuminates and the
display indicates boiler flow temperature.

Central Heating & DHW
(combination boilers or those fitted with a DHW sensor)

Green LEDs for both boiler flow and DHW temperature
illuminate alternately, as shown, and the display shows the
appropriate boiler flow and DHW temperatures.

DHW temp

Ctrl. Position

Approx. Temp.

1.

Boiler flow  temperature (CH)

3 to 9

30

0

C to 90

0

C

2.

DHW (combi boilers or those fitted with DHW sensor)

1 to 8

10

0

C to 80

0

C

2

CONTROL OF WATER TEMPERATURES

The water temperature may be controlled by the following control settings:

Note.

In DHW mode the boiler flow
temperature will automatically
be controlled by the DHW
temperature limiter.

Settings below positions 4 (CH) and 6 (DHW) are NOT RECOMMENDED.

CONTINUED..............................

159181-2.pmd

5/16/2005, 11:36 AM