page
21
700870,700875,700877
SERVICE MANUAL
Portable Air Condi oners
Program Se
ng
Change
Indicaon
Delay me seng of COMP operaon.
EX)If seng is 3mins, it takes 3mins to
be ON aer COMP is OFF.
Deviaon temp seng.
Ex)It operates between 30 c to 34 c( ±2 c),if dF seng is
2 c under 32 c( temp seng).
IC temperature seng
(Frost prevenon sensor)
Temperature Correcon
Temperature Correcon
1-5minutes, control is
available per 1 minute
1 c ~ 5 c
Descripon
the range of seng
Temperature Seng
Program Seng
(Auto restored when no seng is made in each mode)
Power Switch
Target
Temperature
ON/OFF when keep
depressing more than
1 seconds
Keep
depressing
more than
3 seconds
Delay me
Change
Deviaon
temperature
seng
Change
Temperature
dependence
Change
IC temperature
seng
Change
Auto restored when no seng is made in each mode
-10 c ~ +10 c
-10 c ~ +10 c
-5 c ~ +5 c