Remove the waterproofing covers on the outdoor unit quick connectors.
Inspect both quick connectors on outdoor unit and lineset for debri,
clean if necessary.
If debri is allowed to enter system, damage may occur.
Connect the quick connect fittings to the outdoor unit valves with 2 wrenches.
DO NOT OVER TIGHTEN, DAMAGE & LEAKAGE WILL OCCUR.
Remove the brass caps on the two valves with a wrench.
Open the liquid valve & gas valve with an allen wrench.
Reinstall the brass caps on the valves.
Gas leakage Inspection:
After connecting the piping, check all connections & caps for leakage
carefully, soapy water or an electronic refrigerant detector can be used.