background image

Problem

Possible Causes

Solution

The unit 
is not 
working 

Power failure

Wait for the power to be restored

The power switch is off

Turn on the power

The fuse is burned out

Replace the fuse

Remote control batteries are dead

Replace the remote control batteries

The unit’s 3-minute protection has 

been activated 

Wait three minutes after restarting the unit 

Poor cooling 
performance 

Temperature setting may be higher 

than the ambient room temperature  Lower the temperature setting
The heat exchanger on the indoor 

or outdoor unit is dirty 

Clean the affected heat exchanger

The air filter is dirty

Remove the filter and clean it according 

to instructions

The air inlet or outlet of either unit 

is blocked

Turn the unit off, remove the obstruction 

and turn it back on 

Doors and windows are open

Make sure that all doors and windows are 

closed while operating the unit 

Excessive heat is generated by 

sunlight

Close windows and curtains during 

periods of high heat or bright sunshine 

Low refrigerant due to leak or 

long-term use

Check for leaks, re-seal if necessary and 

top off refrigerant 

The unit 
starts and 
stops 
frequently 

There’s too much or too little 

refrigerant in the system  

Check for leaks and recharge the system 

with refrigerant  

There is air, incompressible gas or 

foreign material in the refrigeration 

system  

Evacuate and recharge the system with 

refrigerant

System circuit is blocked

Determine which circuit is blocked and replace 

the malfunctioning piece of equipment 

The compressor is broken

Replace the compressor

Poor heating 
performance 

The outdoor temperature is lower 

than 7°C/44.5°F 

Check for leaks and recharge the system 

with refrigerant 

Cold air is entering through doors 

and windows

Make sure that all doors and windows are 

closed during use  

Low refrigerant due to leak or 

long-term use

Check for leaks, re-seal if necessary and 

top off refrigerant 

Отзывы: