Problem

Possible Causes

Unit does not 
turn on when 
pressing ON/ 
OFF button 

The unit has a 3-minute protection feature that prevents the unit from 

overloading. The unit cannot be restarted within three minutes of being 

turned off. 
Cooling and Heating Models: If the Operation light and PRE-DEF (Pre-heating/

Defrost) indicators are lit up, the outdoor temperature is too cold and the unit’s

anti-cold wind is activated in order to defrost the unit.  
In Cooling-only Models: If the “Fan Only” indicator is lit up, the outdoor 

temperature is too cold and the unit’s anti-freeze protection is activated in 

order to defrost the unit. 

The unit changes 
from COOL mode 
to FAN mode  

The unit changes its setting to prevent frost from forming on the unit. Once 

the temperature increases, the unit will start operating again. 
The set temperature has been reached, at which point the unit turns off the 

compressor. The unit will resume operating when the temperature fluctuates 

again. 

The indoor unit 
emits white mist 

In humid regions, a large temperature difference between the room’s air and 

the conditioned air can cause white mist.  

Both the indoor 

and outdoor units 

emit white mist  

When the unit restarts in HEAT mode after defrosting, white mist may be 
emitted due to moisture generated from the defrosting process. 

The indoor unit 
makes noises 

A squeaking sound is heard when the system is OFF or in COOL mode. The 
noise is also heard when the drain pump (optional) is in operation. 
A squeaking sound may occur after running the unit in HEAT mode due to 
expansion and contraction of the unit’s plastic parts. 

Both the indoor 
unit and outdoor 
unit make noises  

A low hissing sound may occur during operation. This is normal and is caused 

by refrigerant gas flowing through both the indoor and outdoor units. 
A low hissing sound may be heard when the system starts, has just stopped 

running or is defrosting. This noise is normal and is caused by the refrigerant 

gas stopping or changing direction. 

The outdoor unit 

makes noises 

The unit will make different sounds based on its current operating mode.

Dust is emitted from 
either the indoor or 
outdoor unit  

The unit may accumulate dust during extended periods of non-use, which 
will be emitted when the unit is turned on. This can be mitigated by covering 
the unit during long periods of inactivity.  

The unit emits a 
bad odor  

The unit may absorb odors from the environment (such as furniture, cooking, 
cigarettes, etc.) which will be emitted during operations. 
The unit’s filters have become moldy and should be cleaned.

The fan of the 

outdoor unit 

does not operate  

During operation, the fan speed is controlled to optimize product operation.

Отзывы: