ICTeSecurity PRX-TSEC Скачать руководство пользователя страница 1

 
 

PRX-TSE

C

 

tSec Multi-Technology Card Reader   

Installation Manual 
 

Содержание PRX-TSEC

Страница 1: ...PRX TSEC tSec Multi Technology Card Reader Installation Manual...

Страница 2: ...roduced photocopied or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Integrated Control Technology Limited Designed and man...

Страница 3: ...________________________________________________ 10 4 1 Mounting Instructions 10 4 2 Vandal Resistant Cover Mounting 11 5 Wiegand Connection______________________________________________________ 14 6...

Страница 4: ...________ 26 11 European Standards ______________________________________________________ 27 12 UL and ULC Installation Requirements ______________________________________ 28 12 1 CAN ULC S319 05 28 12...

Страница 5: ...ection Keep alive transmission every 30 seconds for intelligent tamper management Fully encapsulated design with environment IP Rating of IP65 for outdoor and indoor operation Bi color LED blue and gr...

Страница 6: ...Sec Extra 125KHz Card Reader PRX TSEC EXTRA 125 KP tSec Extra 125KHz Card Reader with Keypad PRX TSEC EXTRA 125 KP VRC tSec Extra 125kHz Card Reader with Keypad and Vandal Resistant Cover PRX TSEC EXT...

Страница 7: ...re Card Reader PRX TSEC STD DF KP tSec Standard DESFire Card Reader with Keypad PRX TSEC STD DF KP VRC tSec Standard DESFire Card Reader with Keypad and Vandal Resistant Cover Mini PRX TSEC MINI tSec...

Страница 8: ...2 Mifare Modules The Mifare products can be expanded to accommodate large numbers of modules using the encrypted RS 485 Network Modules that are currently available are listed below Integrated Control...

Страница 9: ...transmission flexible memory organization and interoperability with existing infrastructure Fully compliant with the international standard ISO IEC 14443 Type A 1 4 Available in 2 4 and 8 Kbytes EEPR...

Страница 10: ...it 2 Hold the rear case half against the wall and mark the mounting holes and cable entry area The cable entry area should align with a hole cut through the plaster wall board Cables are intended to b...

Страница 11: ...ers are suitable for mounting the tSec card readers on interior or exterior walls i In order to use the capacitive touch keypad with the anti vandal cover you must use the variant that is provided in...

Страница 12: ...C tSec Multi Technology Card Reader Installation Manual June 2017 29mm 1 14 41 5mm 1 63 41 5mm 1 63 29mm 1 14 91 3 58 162mm 6 37 70mm 2 75 8X 5 2mm 0 2 Mounting Holes 22 6mm 0 88 PRX SRVC Vandal Resis...

Страница 13: ...ec Multi Technology Card Reader Installation Manual June 2017 13 120mm 4 72 29mm 1 14 41 5mm 1 63 41 5mm 1 63 29mm 1 14 99mm 3 9 162mm 6 37 8X 5 2mm 0 2 Mounting Holes 22 6mm 0 88 PRX XRVC Vandal Resi...

Страница 14: ...on Default AUX DO L2 D1 L1 BZ YELLOW PURPLE ORANGE WHITE RED GREEN BLACK BROWN BLUE SHIELD 12V 0V DATA 0 DATA 1 GREEN LED BLUE LED BEEPER NA NB Dual LED Connection Using the recommended cables as list...

Страница 15: ...330R 330R WHITE BROWN RED RS 485 Interface i Connect the reader shield to a suitable earth point DO NOT connect the shield to a ground or AUX connection Warning When connecting the Reader in RS 485 Mo...

Страница 16: ...485 USB Converter 2 Power up the card reader and RS 485 USB Converter 3 Open Hyper Terminal or a similar serial terminal program set the communications port to the RS 485 USB Converter and set the par...

Страница 17: ...e to indicate data entry mode has been entered and that you can present the card the required number of times to set the desired option Address Programming Options 1 Card Reading Format 2 Data Output...

Страница 18: ...C key and the available modes will toggle on the screen Setting Description CSN Card serial number CSN or electronic serial number ESN reading converts the serial number of the card to a site code an...

Страница 19: ...ll typically occur however it is recommended to use industry standard 34 Bit 32 Bit Wiegand has no parity or other error checking 34 Bit Wiegand 2 Standard 34 Bit Wiegand data sent on the D0 and D1 da...

Страница 20: ...ault Sector press the G key from the main menu 7 10 Encryption Keys Applies to RS 485 programming mode only You are able to program custom keys in to the Reader by selecting the encryption option prog...

Страница 21: ...d with data in sector 3 The data has a start marker 0xAABBCCDDEEFF at the start of the sector 3 packed decimal BCD encoded site values and ends with 5 unpacked decimal BCD card values It is then fille...

Страница 22: ...the reader press the O key from the main menu 7 14 Output Mode Applies to RS 485 programming mode only The Output Mode defines the output format of the reader Three formats are available Wiegand ICT S...

Страница 23: ...nfigured Wiegand format The b specifier outputs in hexadecimal format In all other cases uppercase means hexadecimal format and lowercase means decimal format The definitions of each specifier is list...

Страница 24: ...he essential details needed to help ensure the correct installation of the tSec Reader tSec Mini tSec Standard tSec Extra 115mm 4 53 tSec Standard tSec Extra 84mm 3 31 tSec Mini 45mm 1 77 tSec Standar...

Страница 25: ...3 125kHz 25mm 0 98 Wiegand Interface Multiple format 26 or 34 Bit data 0 and data 1 card defined Max Cable Distance 150m 492ft Frequency 13 56 MHz ISO IEC 14443 Type A 125KHz pulse width modulated Mul...

Страница 26: ...ard Reader Installation Manual June 2017 10 New Zealand and Australia Intentional Transmitter Product Statement The R NZ compliance label indicates that the supplier of the device asserts that it comp...

Страница 27: ...se of an equivalent new product Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment which could otherwi...

Страница 28: ...ssembly portal locking device s must be evaluated to ULC S533 and CAN ULC S104 Must be installed with CAN ULC S319 Listed portal locking device s for ULC installations Input power must be supplied by...

Страница 29: ...n which can be deter mined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient the receiving antenna Increa...

Страница 30: ...Technology Card Reader Installation Manual June 2017 14 Industry Canada Statement This class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la n...

Страница 31: ...XVRC tSec Extra Vandal Resistant Protective Cover Standard Range PRX TSEC STD tSec Standard Card Reader PRX TSEC STD KP tSec Standard Card Reader with Keypad PRX TSEC STD KP VRC tSec Standard Card Rea...

Страница 32: ...the products and because the products may be used in conjunction with products not manufactured by ICT ICT cannot guarantee the performance of the security system ICT s obligation and liability under...

Страница 33: ...below Integrated Control Technology P O Box 302 340 North Harbour Post Centre Auckland New Zealand 4 John Glenn Ave Rosedale North Shore City 0632 Auckland New Zealand Phone 64 9 476 7124 Toll Free Nu...

Страница 34: ...4 Designers manufacturers of integrated electronic access control security and automation products Designed manufactured by Integrated Control Technology Ltd Copyright Integrated Control Technology Li...