Shield Connection
1.
Connect the reader pigtail shield and cable shield wires together at the reader pigtail splice.
2.
Connect the cable shield to a suitable earth point.
Do not
connect the shield to a ground or AUX connection.
The reader pigtail shield wire is
not
terminated inside the reader.
1
2
3
4
5
6
7
8
9
0
X
Important:
⦁
The card reader must be connected to the module port using a shielded cable.
⦁
The shield must only be connected at one end of the cable in the metallic enclosure (frame grounded).
⦁
Do not connect the cable shield to an AUX-, 0V or V- connection on the module.
⦁
Do not connect the cable shield to any shield used for isolated communication.
⦁
The reader pigtail shield and cable shield wires should be joined at the reader pigtail splice.
⦁
Do not terminate the reader shield wire inside the reader.
TSL Multi-Technology Card Reader | Installation Manual