background image

PROTECTIONS

Overload Protection:

 The Inverter will shut down if the AC output is shorted, or if the 

continuous draw exceeds 300 Watts for more than three seconds. The Inverter can be 
manually reset by turning the Power Switch located on the front panel off, then on. The 
Inverter can supply up to 600 Watts during the overload event, allowing this inverter to start 
larger loads.

Under Voltage Protection:

 The Inverter will shut down if the battery discharges below 10.5 

Vdc (21.0 Vdc for 24V Inverter / 42.0 Vdc for 48V Inverter). The Inverter will automatically 
restart when battery voltage rises to at least 11.8 Vdc (23.6 Vdc for 24V Inverter / 47.2 Vdc for 
48V Inverter).

Over Voltage Protection:

 The Inverter will shut down if the battery voltage exceeds 16.0 Vdc 

(32.0 Vdc for 24V Inverter / 64.0 Vdc for 48V Inverter). The Inverter will automatically restart 
when battery voltage drops below 15.0 Vdc (30.0 Vdc for 24V Inverter / 60.0 Vdc for 48V 
Inverter).

Over Temperature Protection: 

If the Inverter is subjected to higher ambient temperatures 

than than the maximum rated temperature, or if the cooling vents or fan openings are blocked, 
the unit will shut down. The Inverter will automatically restart after the unit cools down.

3

Figure 1: ICT Inverter Front Panel

Figure 2: ICT Inverter Back Panel

POWER SWITCH

AC STATUS LED

(GREEN)

FAULT LED

(RED)

COOLING FAN (TEMPERATURE CONTROLLED)

AC OUTLETS

GROUND CONNECTOR

NEGATIVE DC INPUT

POSITIVE DC INPUT

Содержание SITE INVERTER 300

Страница 1: ...ICT SITE INVERTER 300 855 131 001 INSTRUCTION MANUAL The Power of Reliability INNOVATIVE CIRCUIT TECHNOLOGY LTD ...

Страница 2: ...not exceed the rated load capacity of the Inverter 4CAUTION No user serviceable parts inside Only ICT personnel are authorized to service the unit 4CAUTION It is the installerʼs responsibility to ensure compliance with all applicable installation codes and regulations 4CAUTION Before any connections are made to the unit or system be sure to disconnect the battery terminals Always disconnect the gr...

Страница 3: ...ERTER 300 is designed specifically for communications site applications and includes the following features Two rear facing AC outlets for easy access to the equipment that needs to be powered Rear mounted DC input studs for connection to the DC battery source A grounding stud on the rear of the unit Front mounted power switch and LED indicator lights Thermo controlled ball bearing brushless cooli...

Страница 4: ...6 Vdc for 24V Inverter 47 2 Vdc for 48V Inverter Over Voltage Protection The Inverter will shut down if the battery voltage exceeds 16 0 Vdc 32 0 Vdc for 24V Inverter 64 0 Vdc for 48V Inverter The Inverter will automatically restart when battery voltage drops below 15 0 Vdc 30 0 Vdc for 24V Inverter 60 0 Vdc for 48V Inverter Over Temperature Protection If the Inverter is subjected to higher ambien...

Страница 5: ...d input wire sizes Ensure the positive terminal of the battery is connected to the Positive Input of the inverter and the negative terminal of the battery to the Negative Input of the inverter Incorrect polarity will blow the internal fuse and damage the unit 4 TO AC LOADS IN LINE FUSE BATTERY INVERTER EARTH GROUND Figure 3 ICT Inverter Wiring Diagram 5 Plug your AC loads into the AC Outlets locat...

Страница 6: ... feet 4 AWG 52043 8 AWG 52041 10 AWG 34855 Note Use TE Connectivity Amp part number for Terminal Connector listed in brackets after the wire gauge size or equivalent OPERATION Turn the Power Switch located on the front panel to the ON position The Green LED below the Power Switch should turn on to indicate the inverter is operational Status of LED Indicator Lights AC Status LED Fault LED Status GR...

Страница 7: ...lation if this happens PRODUCT SPECIFICATIONS ICT300 12SNV ICT300 24SNV ICT300 48SNV Input Voltage 10 5 16 0 Vdc 21 0 32 0 Vdc 42 0 64 0 Vdc Output Voltage 115 Vac 5V Output Waveform Pure Sine Wave Output Frequency 60 Hz 0 05 Hz Total Harmonic Distortion THD 3 THD Continuous Output Power 300 Watts Maximum Surge Power 600 Watts for 3 seconds No Load Power Consumption 4 Watts Efficiency full load 90...

Страница 8: ...aterials accurately describe ICT product specifications and capabilities at the time of publication However because of ongoing improvements and updating of ICT products ICT cannot guarantee the accuracy of printed materials after the date of publication and disclaims liability for changes errors or omissions If this ICT product is not in good working order as outlined in the above warranty your so...

Отзывы: