System Settings
Default Operation
The wireless receiver is pre-programmed to work with most access control systems out of the box, using Wiegand
pass through configuration. The factory defaults will provide the following functionality:
⦁
All ICT wireless transmitter signals received will be passed through
Wiegand Port 1
, with the same site code
and a unique user code for each button.
⦁
The relay will activate for 2 seconds when button
4
is pressed.
To immediately use this functionality:
⦁
Connect
Wiegand Port 1
as shown in the
Installation Wiring
section (see previous page).
⦁
Optionally, connect the
Relay NO
to a digital input and the
Relay CM
to your system's input common, for use
as a panic/pendant alarm on button
4
.
⦁
The receiver will pass a unique standard 26 bit Wiegand code to your access control system for each remote
button. Use these to control doors or other functions.
Default Configuration
The default programmed settings are indicated in the table below:
Option
Setting
Default Receiver Mode
ICT Pass Through
RS-232 Default Settings
Baud Rate
9600
Data Bits
8
Parity
None
Stop Bits
1
Flow Control
None
Wiegand Default Settings
Wiegand Port 1
26 Bit Unique User
Wiegand Port 2
26 Bit Unique User
Button Default Settings
Button 1
Wiegand Port 1
Button 2
Wiegand Port 1
Button 3
Wiegand Port 1
Button 4
Relay
Button 5-10 (button combinations)
None
RF-RCVR-433 | Wireless 433MHz Receiver | Installation Manual
7