125kHz Programming Card
125kHz capable tSec Readers can be programmed using a 125kHz programming card, by presenting the card to
the reader in a specified programming sequence.
To use a 125kHz card to program a tSec Reader, the reader must meet the following requirements:
⦁
Firmware version 1.04.229 or higher
⦁
The tSec Reader must have the capability to read 125KHz cards
Using a 125kHz programming card to program a tSec Reader requires a suitably configured 125kHz
programming card. These can be ordered from the ICT customer services team (Ordering code: PRX-PROG-LF).
Programming Summary
To program a tSec Reader using a 125kHz programming card:
1.
You will first need to power cycle the reader you want to program.
2.
Within two minutes of startup, present the programming card to the reader to enter
Programming Mode
.
3.
Wait for the reader to beep twice to indicate that it has entered 125kHz programming mode.
4.
Present the card to the reader the required number of times in the required sequence to apply the desired
programming.
5.
Once complete, allow the programming interface to time out and return to normal operation.
For detailed information on programming tSec Readers using a 125kHz programming card, including the
available programming options and badging sequences, refer to
AN-283: Programming tSec Reader Functions
.
PRX-TSEC Range | tSec Multi-Technology Card Reader with Bluetooth® Technology | Installation Manual
25