7.0 RS485 Wiring Connection 

 
RS485 wiring allows the connection of the Nano Prox to 
the RS232 Serial port over a distance of 900M using an 
ACC-485 RS232/RS485 Converter. Programming of the 
Nano Prox can then be completed using the Nano Prox 
Management Software.  
 

 

 

Figure 4 – RS485 Connection 

 
Using the RS485 serial communications 
connection allows up to eight Nano Prox 
readers to Operate over the same serial 
connection. 

 

8.0 Specifications 

 
Power Supply 
 

Voltage 

 

12VDC (11.5 - 14.0VDC) 

Current 

 

55mA (Peak, Relay On) 

 
Interface 
 

RS232 

 

EIA / RS232 Standard 

 

Distance 

 

15 Meters (55 feet) 

 

RS485 

 

EIA / RS485 Standard 

 Distance 

 900 

Meters 

(2500 

feet) 

 
Relay Output 
 

FORM C 

 

5 AMP Resistive 

 
Cable 

Type    

 

Multi Conductor  22Awg Alpha 5196, 5198 

    18Awg 

Alpha 

5386, 

5388 

    18Awg 

Beldon 

9553 

 

Temperature 
 Operating 

 -35˚- +65˚ Celsius 

 

 

 

-31˚ - 149˚ Fahrenheit 

 
*Specifications are subject to change without notice, 
please visit www.integratedcontroltechnology.com for the 
updated information. For information on programming the 
Nano Prox Series of Proximity Readers in standalone mode 
refer to the appropriate reader installation manual or 
download a copy from the ICT website. 