10
PRT-KLCS
Protege Touchsense LCD Keypad
| April 2014
The system then checks the zones in the area are closed, automatically skipping any open zones that can
be force armed.
Office
Checking zone(s)
If all the zones are closed, the arming process completes.
Office
Arm complete
Once the zones have been armed, the area goes into exit delay.
Office
in EXIT delay
Once the exit delay time has elapsed, the area is force armed.
Office
is FORCE ARMED
Bypassing Zones in an Area
Bypassing allows you to program the alarm system to ignore certain zones the next time the an area is arming
or until the bypass is disabled. For example, you may wish to bypass certain zones when workers are
renovating part of a building
i
The bypass settings of a zone are removed when all the areas the zone is assigned to are disarmed. If
the bypass is a
latched bypass
, the bypass settings remain until removed manually.
Select the Bypass Zones menu by pressing [MENU,7,1].
Press the [RIGHT] key to search for a zone using the zone reference (for example, 000008).
Use the [UP] key to scroll to the next zone.
Warehouse PIR
is not BYPASSED
Press [1] to bypass the zone, press [3] to latch bypass the zone, and press [2] to remove the bypass
setting.
Warehouse PIR
is BYPASSED
Disarming an Area
Select [MENU, 1], and find the area you want to disarm.
Warehouse
is ARMED
If an entry zone is triggered, the area will go into entry delay.
Warehouse
in ENTRY delay