ICT Nano-Prox Скачать руководство пользователя страница 2

WIEGAND CONNECTION 

 
When using the standard Wiegand Interface to the 
access controller or reader expander two wiring methods 
can be used. Dual LED operation allows the signalling of 
both LED's independently using the LED control lines and 
is ideal to show the status of alarm or other integrated 
signals.  

Figure 1 – Dual LED Connection 

 

Single LED allows a single LED line to control both LED 

colours.  

 

Figure 2 – Single LED Connection 

AUX BUTTON INPUT 

 
Button input wiring configuration is shown in Figure 3. For 
programming options refer to the Protégé System Manual 
or the access controller manual for the system that the 
Proximity Reader is connected.  

Figure 3 - Button Input Wiring 

 
Connect a normally open button or switch as shown in 
Figure 3 and complete the programming within the Protégé 
Integrated System for the functionality required.  
 

External Button Input Mode and single LED 
operation must be enabled when using this 
wiring configuration.

 PROGRAMMING

 

 
INSTALLER PROGRAMMING 

 
By default the ICT Proximity Reader is factory configured to 
send data in 26 Bit Wiegand Format, it will read all card 
formats and operate in the dual LED line mode. This 
configuration can be changed to suit system operating 
requirements. 
 

The programming card can only be presented 
within the first 2 minutes from when the card 
reader powers up. 

Entering Program Mode 

To program the Card Reader badge the programming 
card once, the Card Reader will beep to indicate the card 
has been read and then beep twice and illuminate the 
RED LED to indicate programming mode has been 
entered. 

Address Selection

 

To select an address to program the programming card is 
presented to the card reader the number of times 
matching the address number.  
 

Address 

Programming Option 

1 Card 

Reading 

Format 

2 Data 

Output 

Format 

3 LED 

Configuration 

Intelligent Tamper Mode 

Auxiliary Button Input Mode 

6 Operating 

Mode 

Add Standalone Master Card 

RS485 Address  

Door Pre-Alarm Time 

10 

Door Left Open Time 

11 Version 

Information 

12 Default 

 

15 

Client Code Configuration 

 
For example to program address three (LED 
Configuration) the programming card will be presented to 
the card reader three times. 
 
The card reader will then respond by beeping twice and 
flashing the RED LED to indicate data entry mode has 
been entered and that the user should present the card 
the required number of times to set the desired option.  
 

Entering an address value that does not 
exist will result in the reader timing out and 
a long Beep
 tone being generated. 

Data Programming

 

To program a data value in the selected address location 
the same method as the address programming is used. 
Present the Programming Card to the reader the number 
of times matching the data value or option for the 
selected address. The card reader will then respond by 
beeping twice indicating the data was programmed 
correctly and return to the address selection mode. An 
invalid entry will result in a long tone being generated. 
The data can be entered again or allow the Nano Prox to 
timeout to select another address. 