ICT ICT206012-100AI2 Скачать руководство пользователя страница 2

LIMITED WARRANTY

INNOVATIVE CIRCUIT TECHNOLOGY LTD.

26921 GLOUCESTER WAY     LANGLEY, BRITISH COLUMBIA, CANADA     V4W 3Y3

T

 604.856.6303     

F

 604.856.6365     

www.ict-power.com

ICT  Limited  Warranty  is  only  intended  for  the  benefit  of  the  original 
Purchaser  of  this  product.  This  Warranty  is  not  transferable  or 
assignable  without  the  prior  written  permission  of  ICT.  ICT’s  sole 
obligation and liability under this warranty is limited to either repairing 
or  replacing  defective  products  at  the  sole  discretion  of  ICT.  When 
repairing or replacing the products, ICT may use products or parts that 
are  new,  equivalent  to  new  or  re-conditioned.  Parts  repaired  or 
replaced  during  the  warranty  period  will  be  under  warranty  for  the 
remainder of the warranty period.

The warranty period on ICT products purchased new from ICT is two 
years.  The  warranty  period  for  a  repaired  product  or  part  thereof  is 
ninety  (90)  days  or  the  remainder  of  the  unexpired  term  of  the  new 
product warranty period, whichever is greater. Repair or replacement 
of  a  defective  product  or  part  does  not  extend  the  original  warranty 
coverage period. 

No claim will be accepted unless written notice of the claim is received 
by ICT in accordance with ICT’s Return Material Authorization (RMA) 
procedure,  as  soon  as  reasonably  possible  after  the  defect  is 
discovered. A  valid  product  serial  number  must  be  provided  with  the 
RMA  claim  to  prove  eligibility. The  RMA  form  is  available  on  the  ICT 
website at www.ict-power.com/support/warranty-repair/. 

The  Purchaser  shall  at  their  own  risk  and  cost  return  the  defective 
product  to  ICT’s  factory  or  designated  repair  center  once  an  RMA  is 
issued  by  ICT.  Return  of  the  products  to  the  customer  after  repair  is 
completed shall be prepaid by ICT unless otherwise mutually agreed 
between  the  parties.  Products  shipped  to  ICT  which  have  incurred 
freight damage will not be covered by this Warranty and any repairs or 
replacement parts, components or products needed will be invoiced in 
the full current price amount and returned freight collect to Purchaser.  
It is the Purchaser’s responsibility to check the product upon receipt for 
any  damage  during  shipping  and  to  contact  the  carrier  or  shipper 
regarding such damage. Product that is returned as defective, which is 
determined to operate within published specifications will be returned 
to the Purchaser freight collect. 

This Warranty will be void if the product has been subjected to misuse, 
neglect,  accident,  exposure  to  environmental  conditions  not 
conforming to the products’ limits of operation, improper installation or 
maintenance, improper use of an electrical source, defects caused by 
sharp items or by impact pressure, a force majeure event,  has been 
modified  or  repaired  by  anyone  other  than  ICT  or  its  authorized 
representative, has been subjected to unreasonable physical, thermal 
or  electrical  stress,  improper  maintenance,  or  causes  external  to  the 
unit including but not limited to general environmental conditions such 
as  rust,  corrosive  atmospheres,  sustained  temperatures  outside  the 
specified operating range of the equipment, exposure to power surges 
and/or electrical surges, improper grounding, mould or dust, animal or 
insect damage, water damage or immersion in liquid of any kind.

ICT  does  not  control  the  installation  and  use  of  any  ICT  product. 
Accordingly,  it  is  understood  this  does  not  constitute  a  warranty  of 
performance or a warranty of fitness for a particular purpose.

THE

POWER

OF

RELIABILITY

NOTES

Isolated  converters  can  be  used  in  parallel  or  series 
configuration. Please contact ICT for further information.
These converters incorporate a special noise filter design. 
For proper filter operation, the converter must be chassis 
grounded.

4

4

Check for proper voltage at input while converter is under 
load.    This  unit  has  undervoltage  and  overvoltage 
shutdown, so temporary voltage fluctuations outside of the 
rated  input  voltage  range  of  the  unit  will  cause  loss  of 
output.   The  converter  will  automatically  restart  when  the 
input voltage is within range.
Verify the load current.  This converter has current limiting 
so currents exceeding the rated current limit will cause loss 
of  output.     The  converter  will  automatically  restart  when 
the excess load is removed.
Check  the  environment.    This  converter  features  thermal 
shutdown so if the environment is too hot or cooling vents 
are blocked the converter will turn off.  The unit will restart 
when  the  ambient  temperature  is  within  normal  operating 
limits.

4

4

4

TROUBLESHOOTING

Incorrect wiring may result in personal injury or serious 
damage  to  both  the  converter  and  equipment 
connected to the converter.
Do  not  place  unit  on  or  near  sources  of  heat  and 
moisture.
Servicing of unit should be done only at ICT factory.

4

4

4

WARNING

ICT DC SITE CONVERTERS

SETUP

ICT  DC  SITE  CONVERTERS  feature  an  all-new  design  that 
builds on the ICT legacy of reliability and performance. 

ICT  DC  SITE  CONVERTERS  are  fully  isolated.    They  can 
operate from a negative or positive ground electrical system, 
and  are  ideal  for  applications  where  complete  isolation  is 
required between primary and secondary circuits, as well as 
from the chassis.

These instructions should be read before using the product 
and saved for future reference.

Mount converter securely
Do not apply power until unit is completely wired
Connect load to output
Connect power source to input using appropriate fusing 
for  the  application  using  wire  of  size  and  type 
appropriate for the current and length of the connection
The front panel switch turns the unit on and off.  This is 
a  low  current  switch  that  inhibits  the  internal  modules 
but does not interrupt the input power.
A  front  panel  potentiometer  allows  adjustment  of  the 
output voltage.  Always verify the output voltage of the 
system  with  a  meter  while  adjusting  by  connecting 
voltmeter probes to the output terminals of the system.
The  front  panel  LED  is  lit  when  the  output  voltage  is 
within typical operating range.
A remote access terminal is available on the rear of the 
unit that allows remote shutdown of the unit as well as 
monitoring  of  output  voltage  status.    See  the 
“REMOTE/STATUS  CONNECTOR”  section  for  further 
details.

4
4
4
4

4

4

4

4