4. Dimension

Unit : :mm [inch]  

A7 / V7

A7 / V7

Bill Acceptor

Bill Acceptor

94.0[3.70]

83.0[3.27]

11

6.

0[

4.

57

]

8.

0[

0.

31

]

11

5.

0[

4.

53

]

50.8[2.00]

23

9.

0[

9.

41

]

13

2.

0[

5.

20

]

13

.0

[0

.5

1]

48

.6

[1

.3

1]

10

7.

0[

4.

21

]

115.0[4.53] 200bills

  97.0[3.82] 100bills

20

pc

s.

10

pc

s.

130.0[5.12] 400bills

40

pc

s.

190.0[7.48] 800bills

80

pc

s.

51.0[2.008] 

95.0[3.740] 

69.5[2.736] 

4.

0[

0.

15

7]

13

4.

0[

5.

27

6]

7

.5

[0

.2

9

5

]

12

6.

5[

4.

98

0]

78.5 [3.091] 

78.5 [3.091] 

6-R2.65[R0.104] 

         

         

         

         
         

         

         

         

232.0[9.134]

19.5[0.768]

10.0[0.394]

400 pcs.

800 pcs.

200 pcs.

100 pcs.

9.

0[

0.

35

4]

23

.5

[0

.9

25

]

59

.0

[2

.3

23

]

52

.0

[2

.0

47

]

   

17

9.

5[

7.

06

7]

 2

00

 b

ill

s

   

16

1.

5[

6.

35

8]

 1

00

 b

ill

s

   

19

4.

5[

7.

65

7]

 4

00

 b

ill

s

25

4.

5[

10

.0

20

] 8

00

 b

ill

s

5. Installation

  5-1. Harness Application

  

  

  

 

                                        

  

  

Standard 

Pulse

Standard

 Pulse

MDB

5V Enable

ICT Protocol

(RS232)

ICT Protocol

(RS232)

A7

V7

117V AC

117V AC

117V AC

12V DC

12V DC

12V DC

24V AC

34V DC

12V DC

24V AC

Interface 

Model

Used 

Voltage 

Usage

Power & 

*

Data Comm.

Extension Wire

Power & 

*

Data Comm.

Extension Wire

Power & 

*

Data Comm.

**

Power Ext.

*

Data Comm.

Power

**

Power Ext.

*

Data Comm.

Power & 

*

Data Comm.

Extension Wire

Power & 

*

Data Comm.

Extension Wire

Power & 

*

Data Comm.

Power

Extension Wire

*

Data Comm.

Power & 

*

Data Comm.

Extension Wire

Power

GPT Parallel

*

Data Comm. : Data Communication.

**

Power Ext. : Power Extension Wire

***

5RBG-AA203L1-xx : Plug-in Box & Cables, “xx” varies from version to version. 

Table 1

Figure.1

Figure.2

3

www.ictgroup.com.tw 

4

www.ictgroup.com.tw 

WEL-RM008

WEL-RV706

WEL-RM007

WEL-RM012

WEL-RM012

WEL-RM008

CU-R961-1

WEL-RV706

WEL-RM017

WEL-RV701

CU-R961-1

WEL-RV701

WEL-RV706

WEL-RM018

CU-R961-1

WEL-RV703

WEL-RV702

WEL-RM007

WEL-RM006

CU-R961-1

Harness

Page

5

6

7

8

9

7

11

5

6

11

12

8

14

13

15

11

7

11

16

10

6

***

5RBG-AA203L1-xx

Содержание A7 Series

Страница 1: ...Vertical Horizontal A7 V7 ie Ser s Installation Guide Bill Acceptor International Currency Technologies Corp 2003 International Currency Technologies Corporation V 11 0 Part Number H4459J R...

Страница 2: ...as ICT deems necessary to satisfy any applicable law regulation legal process or governmental request or to edit refuse to post or to remove any information or materials in whole or in part in ICT s...

Страница 3: ...um 36 W Four way acceptance See Page 3 Approx 100 bills 80 120 200 bills 200 300 400 bills 350 450 800 bills 750 850 Standard Pulse 5V Enable ICT Protocol MDB GPT Parallel Approx 1 25kg General Mechan...

Страница 4: ...Protocol RS232 ICT Protocol RS232 A7 V7 117V AC 117V AC 117V AC 12V DC 12V DC 12V DC 24V AC 34V DC 12V DC 24V AC Interface Model Used Voltage Usage Power Data Comm Extension Wire Power Data Comm Exten...

Страница 5: ...EARTHGROUND 1 2 3 4 5 6 7 8 9 AMP 172340 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 BLK 15 2 KEY A7 V7 A7 V7 Bill Acceptor Bill Acceptor 5 www ictgroup com tw 6...

Страница 6: ...Reserved P IN 5 RED 12V DC Power P IN 5 Dotted BLACK 12V DC Power P IN 6 Reserved P IN 7 BLUE CREDIT_RELAY N O P IN 8 PURPLE CREDIT_RELAY Common P IN 9 BROWN GND Power P IN 9 Dotted WHITE GND Power S...

Страница 7: ...LLOW NEUTRAL INHIBIT PIN 10 BROWN GND PIN 16 BLUE CREDIT RELAY NO PIN 20 BLACK 115VAC HOT POWER IN PIN 21 GREEN EARTH GROUND PIN 27 28 29 RED I ENABLE L PIN 13 14 15 25 BLACK I ENABLE H 5V Enable 117V...

Страница 8: ...roup com tw 12 www ictgroup com tw WEL RV701 DC 12V WEL RV701 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 BLK 15 2 1 2 3 4 5 6 7 8 9 AMP 172340 1 AMP 551 inch or 1...

Страница 9: ...eserved P 2 INHIBIT YELLOW P 3 Reserved P 4 CREDIT_RELAY N O BLUE P 5 CREDIT_RELAY Common PURPLE GREEN P 5 INHIBIT P 6 Reserved P 7 24V AC RET ORANGE P 8 24V AC HOT RED P 9 Reserved IN IN IN IN IN IN...

Страница 10: ...CABLE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 BLK 15 2 2 54mm KEY PIN 1 BLUE CH1 PIN 2 YELLOW CH2 PIN 3 WHITE CH3 GREEN BLUE YELLOW WHITE ORANGE BLACK WHITE B...

Страница 11: ...nterface Figure 15 Figure 16 Credit O P Credit_Relay_NO Inhibit BA Status DIP SW Setting Control Signal Inhibit Active Inhibit Active Low Low Low High High High High Low Inhibit Enable Inhibit I P Hi...

Страница 12: ..._ENABLE 1_ENABLE_H 2_ENABLE_H 5_ENABLE_H 2_ENABLE_L 5_ENABLE_L 1_ENABLE_L HiZTR ON HiZTR ON HiZTR ON LoZTR OFF LoZTR OFF LoZTR OFF 2_ENABLE 5_ENABLE 2 5 5_CREDIT A7 V7 A7 V7 Bill Acceptor Bill Accepto...

Страница 13: ...R ON LoZTR OFF MDB Interface GPT Parallel Interface GPT System Serial to Parallel Converter 5V VEND1 4 INHIBIT 12V TXD RXD Customer Side Customer Side Customer Side Bill Acceptor Bill Acceptor Bill Ac...

Страница 14: ...the package for more detail A7 V7 FP 001 PC Power must be applied to BA AFTER connecting 1 2 3 4 ON DIP Firmware Power WEL RM009 WEL R087 COM1 or COM2 PH 5 4 3 2 1 9 8 7 6 To make sure the bill accept...

Страница 15: ...ead error Inspect for foreign objects on Magnetic Head and clean Inspect for right DIP switch setting Inspect for foreign objects on sensor or bill path and clean Replace the bill box Empty the bill b...