F/N 521599 Oct 07
© 2007 ICS, Blount Inc.
P95 OPERATOR’S MANUAL
9
REQUIREMENTS
HTMA REQUIREMENTS
TOOL CATEGORY
Hydrualic System Requirements
TYPE I
TYPE II
TYPE III
TYPE RR
Flow Rate
4-6 gpm
(15-23 l/min)
7-9 gpm
(26-34 l/min)
11-13 gpm
(42-49 l/min)
9-10.5 gpm
(34-40 l/min)
Tool Operating Pressure
(at the power supply outlet)
2000 psi
(138 bar)
2000 psi
(138 bar)
2000 psi
(138 bar)
2000 psi
(138 bar)
System Relief Valve Setting
(at the power supply outlet)
2100-2250 psi
(145-155 bar)
2100-2250 ps
(145-155 bar)i
2100-2250 psi
(145-155 bar)
2200-2300 psi
(152-159 bar)
Maximum Back Pressure
(at the tool end of the return hose)
250 psi
(17 bar)
250 psi
(17 bar)
250 psi
(17 bar)
250 psi
(17 bar)
Measured at max. fluid viscosity of:
(at min. operating temperature)
400 SSU*
(82 CST)**
400 SSU*
(82 CST)**
400 SSU*
(82 CST)**
400 SSU*
(82 CST)**
Temperature
Sufficient heat rejection capacity to limit
max. fluid temperature to: (at max. expected
ambient temp.)
140˚ F
(60˚ C)
140˚ F
(60˚ C)
140˚ F
(60˚ C)
140˚ F
(60˚ C)
Minimum Cooling Capacity
(at a temperature difference of between
ambient and fluid temps)
3 hp (2.24 kW)
40˚ F (22˚ C)
5 hp (3.73 kW)
40˚ F (22˚ C)
7 hp (4.47 kW)
40˚ F (22˚ C)
6 hp (5.22 kW)
40˚ F (22˚ C)
NOTE
: DO NOT operate the tool at oil temperature above 140˚ F (60˚ C).
Operation at higher temperatures can cuase operator discomfort at the tool.
Filter
25 microns
25 microns
25 microns
25 microns
Minimum Full-Flow Filtration
Sized for Flow at Least:
(for cold temp. start-up and max. dirt holding
capacity)
30 gpm
(114 l/min)
30 gpm
(114 l/min)
30 gpm
(114 l/min)
30 gpm
(114 l/min)
Hydraulic Fluid
(Petroleum based; premium grade, anti-wear,
non conductive)
100-400 SSU*
(20-82 CST)**
100-400 SSU*
(20-82 CST)**
100-400 SSU*
(20-82 CST)**
100-400 SSU*
(20-82 CST)**
NOTE
: When choosing hydraulic fluid, the expected oil temperature extremes that will be experienced
win service determine the most suitable temperature viscosity characteristics. Hydraulic fluids with a
viscosity index over 140 will meet the requirements over a wide range of operating temperatures.
*SSU = Saybolt Seconds Universal
**CST = Centistokesl
NOTE:
These are general hydraulic sysem requirements.
See tool Specification page (page 6) for tool specific requirements.
C
20 l/min @138 bar
BHTMA CATEGORY
D
30 l/min @138 bar
BHTMA CATEGORY