18
WIKA operating instructions pressure transmitter, model P-3x
11473500.07 01/2020 EN/DE/FR/ES
EN
Circular connector M12 x 1 (4-pin)
2-wire
3-wire
U+
1
1
U-
3
3
S+
-
4
Angular connector DIN 175301-803 A
2-wire
3-wire
U+
1
1
U-
2
2
S+
-
3
Circular connector M16 x 0.75 (5-pin)
2-wire
3-wire
U+
3
3
U-
1
4
S+
-
1
Circular connector M12 x 1 (5-pin), CANopen
2-wire
U+
2
U-
3
Shield
1
CAN-High
4
CAN-Low
5
Cable outlet unshielded
2-wire
3-wire
U+
brown
brown
U-
blue
blue
S+
-
black
Cable lengths on request.
6. Commissioning, operation
6.2 Making the electrical connection
■
The instrument must be earthed via the process connection.
■
Select a cable diameter that matches the cable gland of the connector. Make sure that the cable
gland of the mounted connector has a tight fit and that the sealings are present and undamaged.
Tighten the threaded connection and check that the seal is correctly seated, in order to ensure a
tight seal.
■
For cable outlets, make sure that no moisture enters at the cable end.
Connection diagrams
Содержание P-3 Series
Страница 91: ...91 11473500 07 01 2020 EN DE FR ES ES ...
Страница 92: ......