to the shaft, but do not over tighten. Ensure that the various O-Rings on the Shaft are not
damaged, and are in their correct O ring seat.
f.
Ensure that HEX HEAD BOLTS on right hand side of the base looking from wet end are
sufficiently tight to hold Bearing Assembly horizontal, but not lock it. Move Bearing Assembly
back by adjusting nut on Adjusting Screw (MMAB) to temporarily clamp Frame Plate Liner
Insert in its correct position.
All sizes up to and including 4x3 Pumps.
IV.
Fit VOLUTE LINER (MMVOL) – Gently place Volute Liner over Impeller so that it cannot drop down
and cause injury. Move it back towards Frame Plate until the conical bore engages with the matching
periphery of the Frame Plate Liner Insert. Ensure that the Volute Liner Seal (‘O’ Ring) has not been
displaced. Fit a G clamp to temporarily clamp the Volute Liner discharge nozzle to the flange of the
Frame Plate, as shown in Fig 11.
NOTE: THIS WILL PREVENT DROPPING THE VOLUTE AND CAUSING POTENTIAL
INJURY OR DAMAGE.
V.
Lift COVER PLATE (MMCP)
over Volute Liner and align
bolt holes with Cover Plate
Bolts that were earlier fitted to
Frame Plate. Fit nuts to Cover
Plate Bolts, and leave loose.
Remove G clamp supporting
Volute Liner, and tighten
Cover Plate.
VI.
Complete the assembly of
gland flush or greasing. The
pump is now ready for fitting
of Joint Rings (refer Figure 12)
and Impeller adjustment.
Figure 11-
G Clamp Volute Liner to Frame Plate
ENSURE THAT THE VOLUTE LINER IS FIRMLY CLAMPED DURING ASSEMBLY TO PREVENT INJURY