Страница 1: ...at www icsweargroup com Or contact us directly at info icsweargroup com 1 ASSEMBLY OPERATING MAINTENANCE AND TESTING INSTRUCTIONS ICS Mill Master Slurry Pumps MANUAL FOR METAL AND RUBBER PUMP SIZES IC...

Страница 2: ...pump is operating with a very hot or very cold liquid gradually change pump temperature to prevent damage by thermal shock Thermal shock may cause personnel injury or equipment damage NOTE Proper ali...

Страница 3: ...SSEMBLY 8 4 1 1 FITTING BEARING ASSEMBLY TO BASE Ref Fig 1 8 4 1 2 FITTING FRAME PLATE AND COVER PLATE BOLTS Ref Fig 2 10 4 2 SEAL ASSEMBLY 12 4 2 1 GLAND SEAL ASSEMBLY Ref Fig 4 12 4 2 2 EXPELLER SEA...

Страница 4: ...ct layouts consult ICS for your pumps specific bill of materials Bearing Assembly Description ICS Part Number Bearing MMBR Bearing Drive End MMBRD Bearing Housing MMBH Bearing V Seal MMBRS End Cover M...

Страница 5: ...haft O Ring MMSOR Shaft Sleeve Spacer MMSTS Stuffing Box MMSBOX Metal Wet End Kit and Frame Assembly Description ICS Part Number Adjusting Screw MMAB Base MMBAS Clamp Bolt MMCLB Clamp Washer MMCLW Cot...

Страница 6: ...amp Bolt MMCLB Clamp Washer MMCLW Cotters MMCOT Cover Plate MMCP Cover Plate Bolt MMCPB Cover Plate Liner MMCPL Cover Plate Liner Stud MMCPLS Discharge Seal Ring MMDJR Frame Plate MMFP Frame Plate Lin...

Страница 7: ...nge of ICS Heavy Duty Mill Master Slurry Pumps include Cartridge type upgraded ICS Bearing Assembly for extended life compared to competitors pumps Replaceable casing liners hard metal rubber or ureth...

Страница 8: ...hould be cleaned and if necessary re painted Matching faces should be free of rust dirt and burrs and have a coating of anti seize compound applied prior to assembly so that the pump remains easy to f...

Страница 9: ...Housing ears with the hold down bolt holes in the base then lower the Bearing Assembly into the Base and ensure the lug has fitted over the Adjusting Screw and between the nuts and washers iv Fit Cla...

Страница 10: ...e corresponding Base arms For pumps 6x4 and larger Frame Plates are provided with either radially tapped holes for eyebolts or lifting lugs to assist fitting ii Insert Frame Plate Studs or Frame Plate...

Страница 11: ...the full effort of an average man approximately 70kg using a standard podger spanner or by a few impacts from an impact wrench after initial slackness in the nut has been taken up Make corresponding p...

Страница 12: ...in your specific application 4 2 1 STUFFING BOX SEAL ASSEMBLY Ref Fig 4 Figure 4 Assemble Gland Seal For longevity ALL gland packed pumps require a reliable external water flush as detailed in Append...

Страница 13: ...up com 13 FULL FLOW STANDARD Used for normal slurry applications with positive suction head or suction lifts to approx 2m Figure 5 Full Flow Arrangement LOW FLOW As full flow except lantern restrictor...

Страница 14: ...flattening each ring separately until they almost completely fill the Stuffing Box chamber Ultra Low Flow Packed Glands 1 Place Neck Ring into stuffing box bore 2 Place Lip Seal into stuffing box bor...

Страница 15: ...O ring and if applicable Impeller Release Collar to the pump shaft then fit the Stuffing Box you have assembled to the Frame Plate engaging Shaft Sleeve with Shaft and tap into position in Frame Plat...

Страница 16: ...l depending upon pump and frame size Please contact an ICS Wear Group representative to discuss you site specific requirements Figure 8 Assemble Expeller Sealed Pump The following instructions describ...

Страница 17: ...t the Expeller Ring you have assembled to the Frame Plate and tap into position with a soft mallet IX Locate Expeller Ring with the grease inlet connection at the top X Check that all Shaft O Ring bef...

Страница 18: ...Plate Liner If Studs are not square to the face of the Liner screw a nut on the thread and straighten by tapping lightly with a hammer II Lift Liner in position line up the Studs with holes in the Fra...

Страница 19: ...p with the Cover Plate 3x2 and 4x3 pumps only then push elastomer intake flange through the Cover Plate bore Press down until the Cover Plate Liner firmly engages with the Cover Plate and the elastome...

Страница 20: ...iner Seal comprises an O ring for these small sizes except the 4x3 which has a C section seal III Fit Frame Plate Liner Insert The Frame Plate Liner Insert is clamped in position by engagement of its...

Страница 21: ...nd are sufficiently tight to hold Bearing Assembly horizontal but not lock it Move Bearing Assembly back by adjusting nut on Adjusting Screw MMAB to temporarily clamp Frame Plate Liner Insert in its c...

Страница 22: ...and cause injury Move it back towards Frame Plate until the conical bore engages with the matching periphery of the Frame Plate Liner Insert Ensure that the Volute Liner Seal O Ring has not been disp...

Страница 23: ...nents I The INTAKE JOINT RING MMINJR and DISCHARGE JOINT RING MMDJR are supplied loose with pumps requiring these items Fit Intake Joint Ring and Discharge Joint Ring as shown in Fig 15 using contact...

Страница 24: ...ise as viewed from the drive end by hand and move the Bearing Assembly forward towards the pump suction by adjusting the rear nut on the ADJUSTING BOLT MMAB until the Impeller rubs on the front Liner...

Страница 25: ...eriodic adjustment of Impeller clearance over its operating life is an important factor in maximizing wear life of both Impeller and front Liner Regular Impeller adjustment has shown an increase in we...

Страница 26: ...eal arrangement shown in Fig 4 c has a ring of packing between the Lantern Ring and the pump casing interior to limit gland sealing water flow rate to a very small value typically about one percent of...