Power Blower Data
TYPE:
Positive Pressure Ventilator
BLADE:
Air Flex Fiberglass Reinforced Polyamide High Strength Blades, Die
Cast Aluminum or Polypropylene.
BUSHING:
Keyed Shaft and Set or Cap Screws.
SHROUD:
Turbo 2000 Tapered Aluminum.
DRIVE:
Industrial-Type, Straight-Banded V-Belt.
BEARINGS:
Locking, Self-Aligning and Permanently Lubricated.
FRAME:
Rugged, Lightweight, Square-Steel Tubing with Powder-Coat Finish.
GRILL:
Continuous Circular-Wound, External-Weld Steel Wire with 8 Tie
Points for Additional Safety.
VIBRATION DAMPENERS:
Steel-Reinforced Rubber.
Electric Blowers:
All electric motors are single phase, 60 Hz, rigid base, 56 frame with ball and
bearings and manual reset overload protection.
ELECTRIC
UNITS
ENGINE
HP
CFM
S/B
RPM
WIDTH DEPTH HEIGHT
LBS
EBS-16
ELECTRIC
1/3 TEFC
3,200
N.A.
1,736
18.75
14.25
19.50
47
EB-16-VSG
ELECTRIC
1.5 TEFC
0 - 11,125
7
3,150
19.25
19.25
21.25
83
Electric Blower Power Requirements*
Based on 115 v blower on a 20 amp circuit.
Blower
Model
Motor
HP
Starting
Amps
Starting
Watts
Running
Amps
Running
Watts
EBS-16
1/3 TEFC
10.9
6,300
6.3
756
EB-16-VSG
1.5 TEFC
48
6,000
176
1,900
*Starting amps and watts are momentary
Maximum Power Cord Length (in feet) **
Motor HP
14
Gauge
12
Gauge
10
Gauge
8
Gauge
6
Gauge
1/3
215'
330'
550'
850'
1,350'
1.0
60'
95'
150'
240'
380'
** Calculations based on one blower connected to 20 amp circuit.
-4-