![ICS 695GC/F4 Скачать руководство пользователя страница 66](http://html1.mh-extra.com/html/ics/695gc-f4/695gc-f4_service-manual_3553851066.webp)
©2012 ICS - Blount Inc, Specifications subject to change without notice. REV11272012 P/N 546529
66
695GC/F4 SERVICE MANUAL
20.10
Using soapy water on both sides, per-
form a crankcase leak down test using
pressure gauge and vacuum gauge.
20.12
Crankcase separation.
The universal puller and grip plate are
required to separate the crankcase.
20.11
Use pressure gauge to perform a leak
down test. Pressure should hold at 7 psi
(0.5 bar).
20. CRANKCASE