background image

GPIB commands except for Remote with Lockout and 

Local with Lockout.  The user will have to be sure that 

the instrument supports the device commands used 

in the existing program and that the device messages 

sent to the 4865 are terminated with the 488.2 New 

Line terminator.

Connections

While the 4865 is normally used in a back-to-back 

connection with its companion instrument as shown 

in Figure 1, it can be connected to the instrument in 

other ways.  

Figure 2 shows the 4865 connected to the instrument 

through a hub.  This is a typical lab bench connection.  

It lets the user confi gure the 4865 through the hub 

while developing the GPIB program.

Figure 3 shows the 4865 connected to the instru-

ment over  a company network.  The 4865 gives you 

standard  GPIB  control  over  a  LAN  instrument  no 

matter where it is located.

4865's Operation

The 4865 transparently passes all device commands 

and IEEE-488.2 Common Commands onto the instru-

ment and returns all instrument responses to the client 

application. The 4865 also does such familiar GPIB 

tasks as sending Selected Device Clears and Device 

Triggers to the instrument, set Local or set Remote 

modes  and  perform  Serial  Polls.    Interface  Clears 

(IFCs) only affect the 4865's GPIB Interface and are 

not passed on to the companion instrument.  

The  4865  does  a  background  poll  of  the  LAN 

instrument's  Status  Register  and  asserts  the  GPIB 

bus SRQ line if a Service Request is detected.  When 

the 4865 is Serial Polled, the instrument is sent a 

de-

vice_readSTB

 rpc and the response is returned to the 

GPIB Controller.

Setup & Installation

The 4865 is very easy to install.  Plug the 4865 into 

a network access point adjacent to your computer as 

shown in Figure 2 or use an Ethernet crossover cable 

to connect the 4865 directly to a PC's network port. 

Launch a web browser and point it to the 4865's default 

AutoIP address of 169.254.48.65.  The 4865's Welcome 

page provides all of the information about the 4865's 

current settings.  On the Confi guration page, you can 

set the 4865 to a static IP address or enable the 4865 

to accept an DHCP address setting if the network has 

a server that can assign network addresses.  You can 

also set the 4865's GPIB address and a fi xed IP address 

for the companion instrument if that works better in 

Figure 2     4865 Instrument Hub Connection

Figure 3    4865 Instrument Network Connection

4865 APPLICATIONS

your environment.    Set the remaining network parameters, save the 

settings and the 4865 is ready to be connected to the instrument and 

GPIB bus.

A rear panel LAN Reset button is provided to reset the 4865's 

network settings to the factory default settings in case the 4865's 

confi guration needs to be reset.

Easy Firmware Updates

The 4865 has a program download and store function which lets 

the 4865 receive program changes through its Ethernet interface.  If a 

future fi rmware change is necessary, the new fi rmware and Upgrade 

Utility program can be downloaded from ICS's website.  The 4865 

validates the new code before saving it in its Flash memory. 

Network Features

The 4865 uses the VXI-11 protocol or RPC over TCP/IP to com-

municate with the test program (client application).  The TCP trans-

portation layer and IP protocol guarantees error free communication 

with the 4865 over the network or Internet as long as the connection 

is maintained.   

4865 LAN <=>GPIB Interface

GPIB

LAN Instrument

��������������

���������������

Line to Company Network

8065 Ethernet to GPIB

���������������������

4865 LAN <=>GPIB Interface

GPIB

LAN Instrument

��������������

���������������

8065 Ethernet to GPIB

Company Network

Отзывы: