background image

Page - vii

Advisories

Three types of advisories are used throughout the manual to stress important points or warn of potential
hazards to the user or the system. They are the Note, the Caution, and the Warning. Following is an example
of each type of advisory:

Note:

The note is used to present special instruction, or to provide extra information which may
help to simplify the use of the product.

       CAUTION!

 

A Caution is used to alert you to a situation which if ignored may cause injury or
damage equipment.

       WARNING!

 

A Warning is used to alert you of a situation which if ignored will

 

cause serious injury.

Cautions and Warnings are accented with triangular symbols. The exclamation symbol is used in all cautions
and warnings to help alert you to the important instructions. The lightning flash symbol is used on the left
hand side of a caution or a warning if the advisory relates to the presence of voltage which may be of
sufficient magnitude to cause electrical shock.

Use caution when servicing any electrical component. We have tried to identify the areas which may pose
a Caution or Warning condition in this manual; however, ICS Advent does not claim to have covered all
situations which might require the use of a Caution or Warning.

You must refer to the documentation for any component you install into a computer system to ensure proper
precautions and procedures are followed.

Содержание RB-24

Страница 1: ...Model RB 24 Product Manual MANUAL NUMBER 00650 130 2B...

Страница 2: ...ual in our online Support Library Thank you The information in this document is provided for reference only ICS Advent does not assume any liability arising from the application or use of the informat...

Страница 3: ...Page iv This page intentionally left blank...

Страница 4: ...ts which are not in an as new and re saleable condition are not eligible for credit return and will be returned to the customer Limited Warranty Effective April 1 1998 all products carry a 2 year limi...

Страница 5: ...made by various manufacturers in performing warranty repairs and building replacement products If ICS Advent repairs or replaces a product its warranty term is not extended ICSAdvent will normally re...

Страница 6: ...Cautions and Warnings are accented with triangular symbols The exclamation symbol is used in all cautions and warnings to help alert you to the important instructions The lightning flash symbol is us...

Страница 7: ...Page viii This page intentionally left blank...

Страница 8: ...Page ix Table of Contents Chapter 1 Installation 1 1 Chapter 2 Functional Description 2 1 Chapter 3 Connector Pin Assignments 3 1 Chapter 4 Specifications 4 1 Current Revision 2B December 2000...

Страница 9: ...Page x This page intentionally left blank...

Страница 10: ...niques be used cable conected to ground at the aperture of the digital I O card that will provide signals twisted pair wiring etc Power Connections Connector J3 is provided for easy application of 5 V...

Страница 11: ...Manual Number 00650 130 2 Page 1 2 RB 24 Manual RB 24 Layout...

Страница 12: ...ith each relay glows when that relay is actuated SPDT Form C relays are standard but DPDT Form C relays are an available option The relays used are UL recognized non latching polarized units designed...

Страница 13: ...as follows 10 OUT H313 H80 Sets the ports to use as outputs 20 OUT H310 1 Activates Port A bit 0 Relay 0 30 OUT H311 16 Activates Port B bit 4 Relay 21 Alternatively any parallel TTL compatible source...

Страница 14: ...computer The mating connectors are a type AMP 1 746285 0 or equivalent 50 pins or type AMP 745242 1 37 pins for insulation displacement flat cables or Cannon DC37 S 37 pins for soldered connections P...

Страница 15: ...ons for the 37 pin connector are as follows 3 1 66 10 17 3 1 66 10 17 1RW 8VHG 1RW 8VHG 1RW 8VHG 1RW 8VHG 5HOD LJLWDO RPPRQ 5HOD 5HOD 5HOD 5HOD 5HOD 5HOD 5HOD 5HOD 5HOD 5HOD 5HOD 5HOD 5HOD 5HOD LJLWDO...

Страница 16: ...ety practice should be followed if AC voltages are to be switched by the relays Actuate Time nominal voltage 6 milliseconds max including bounce Release Time nominal voltage 8 milliseconds max includi...

Страница 17: ...Manual Number 00650 130 2 Page 4 2 RB 24 Manual Environmental Operating Temperature Range 0o to 60o C Storage Temperature Range 50o to 120o C Humidity 45 to 85 RH non condensing...

Страница 18: ...ternal Win32IRQ dll index 1 function DetectIRQ Boolean stdcall external Win32IRQ dll index 2 function SendEOI Boolean stdcall external Win32IRQ dll index 3 In C the library file Win32IRQ lib must firs...

Страница 19: ...ogram needs to continue running while waithing for DetectIRQ a separate thread should be spawned from which to call DetectIRQ The return result is TRUE if an IRQ was successfully detected on the given...

Страница 20: ...N61000 4 3 1995RadiatedRFFieldImmunity EN61000 4 4 1995EFTImmunityforACandI OLines EN 60950 1992 Safety of InformationTechnology Equipment Thetechnicaldocumentationrequiredtodemonstratethisproductmeet...

Отзывы: