Manual Number: 00750-123-1
Page 8
COMM4AT/EX Manual
If your communications package allows the use of Baud rate divisors, choose the appropriate divi-
sor from the following table:
For this Data Rate
Choose this Divisor
1200 bps
384
2400 bps
192
4800 bps
96
9600 bps
48
19.2K bps
24
38.4K bps
12
57.6K bps
8
115.2K bps
4
230.4K bps
2
460.8K bps
1
Baud Rates and Divisors for the Div2 mode
The following table shows some common data rates and the rates you should choose to match them
if using the adapter in the Div2 mode.
For this Data Rate
Choose this Data Rate
1200 bps
600 bps
2400 bps
1200 bps
4800 bps
2400bps
9600 bps
4800 bps
19.2K bps
9600 bps
38.4K bps
19.2K bps
57.6 K bps
38.4K bps
115.2 K bps
57.6 K bps
230.4 K bps
115.2 K bps
If your communications package allows the use of Baud rate divisors, choose the appropriate divi-
sor from the following table:
For this Data Rate
Choose this Divisor
1200 bps
192
2400 bps
96
4800 bps
48
9600 bps
24
19.2K bps
12
38.4K bps
8
57.6K bps
4
115.2K bps
2
230.4K bps
1
Содержание COMM4AT/EX
Страница 1: ...Model COMM4AT EX Product Manual MANUAL NUMBER 00750 123 1B...
Страница 9: ...Manual Number 00750 123 1 Page 2 COMM4AT EX Manual This page intentionally left blank...
Страница 17: ...Manual Number 00750 123 1 Page 10 COMM4AT EX Manual This page intentionally left blank...
Страница 21: ...Manual Number 00750 123 1 Page 14 COMM4AT EX Manual This page intentionally left blank...
Страница 23: ...Manual Number 00750 123 1 Page 16 COMM4AT EX Manual This page intentionally left blank...
Страница 25: ...Manual Number 00750 123 1 Page 18 COMM4AT EX Manual This page intentionally left blank...
Страница 27: ...Manual Number 00750 123 1 Page 20 COMM4AT EX Manual This page intentionally left blank...
Страница 28: ...Manual Number 00750 123 1 Page 21 Appendix D Silk Screen...
Страница 29: ...Manual Number 00750 123 1 Page 22 COMM4AT EX Manual This page intentionally left blank...