background image

Connecting the LEX unit to the REX unit 

   

To ensure proper operation, the maximum length of the fiber optic cable, including patch cords, must not exceed 10km. 

 

 The cabling must provide a duplex connection with crossover and must be terminated with Duplex LC 

 

connectors at both ends.

With Surface Cabling

1. 

Plug one end of the fiber optic cabling (not included) into the Link port on the LEX unit.

2. 

Plug the other end of the fiber optic cabling into the Link port on the REX unit.

With Premise Cabling

1. 

Plug one end of a fiber optic patch cord (not included) into the Link port on the LEX unit.

2. 

Plug the other end of the patch cord into the fiber optic information outlet near the host computer.

3. 

Plug one end of the 2

nd

 fiber optic patch cord (not included) into the Link port on the  

 

REX unit.

4. 

Plug the other end of the 2

nd

 patch cord into the fiber optic information outlet near the USB device.

      
 

Checking the Installation

1. 

On the LEX and REX units, check that the Power, Host, and Link LEDs are on and that the Activity LED 

 

is blinking. If the Link LED is permanently off, then the cabling between the LEX and REX unit is not 

 

installed properly or is defective.

2.  

For Windows users (2000, XP,  Vista, Windows 7), open Device Manager to confirm that the Ranger 

 

2244 has installed correctly. Expand the entry for Universal Serial Bus controllers by clicking the +  

 

sign. If the Ranger 2244 has been installed correctly, you should find it listed as a “Generic USB Hub”.

3. 

For Mac OS X users, open the System Profiler to confirm that the Ranger has installed correctly.  In  

 

 

the left hand column under Hardware, select “USB” and inspect the right hand panel. If the Ranger  

 

2244 has been installed correctly, you should find it listed as a “Hub” under the USB High-Speed Bus/ 

 

USB Bus.

4. 

If the Ranger 2244 is not detected correctly or fails to detect, please consult the Troubleshooting 

 

Guide.

 

To open System Profiler in OS X: Open the Finder, select Applications, then open the Utilities folder and double 

 

click on the System Profiler icon.

 

To open Device Manager in Windows 2000 or XP: 

 

Right click “My Computer” then select:  Properties >> Hardware tab >> Device Manager

  

To open Device Manager in Windows Vista or Windows 7: 

 

Open the Start menu, right click on “Computer” then select:  Manage >> Device Manager

note

note

7

Содержание USB Ranger 2244

Страница 1: ...USB Ranger 2244 Fiber Optic USB 2 0 Extender User Guide Powered by ...

Страница 2: ... to which this declaration relates is in conformity with European Standard EMC EN 55022 2006 A1 2007 Class B EN 61000 3 2 2006 EN 61000 3 3 2003 and EN 55024 1998 A2 2003 IC Statement This Class B digital apparatus complies with Canadian ICES 003 2010 Icron Technologies Corporation All rights reserved Icron Technologies Corporation the Icron Technologies Corporation logo and the Icron Technologies...

Страница 3: ...unit 6 Installing the REX unit 6 Connecting the LEX unit to the REX unit 7 Checking the Installation 7 Connecting a USB Device 8 Troubleshooting 8 Specifications 11 Limited Hardware Warranty 12 Hardware Remedies 12 Limitation of Liability 12 Obtaining Warranty Service 13 Contacting Technical Support 13 Technical Glossary 14 ...

Страница 4: ...o complete the installation you will also require the following items that are not included with the product USB 1 1 or 2 0 compatible computer host computer with a USB compliant operating system USB 1 1 or 2 0 compatible device 2 strand fiber optic cable with Duplex LC connectors if using surface cabling OR 2 strand fiber optic cabling with two information outlets and two 2 strand fiber optic pat...

Страница 5: ... 4 Activity LED Amber Indicates activity when data transmission is active between LEX and REX LED blinks intermittently with or without a USB device connected When the LEX and REX are in suspend mode the LED is off 5 Earth Ground Optional earth ground connection to housing of unit Accepts an M2 type screw 6 Power port optional Not required in normal operation An optional 5V power supply can be con...

Страница 6: ... the attached USB device attempts to draw more than the 500mA current 3 Power LED Blue LED turns on when power is supplied Off when no power is supplied 4 Link LED Green Indicates a valid ExtremeUSB link is established between the LEX and REX 5 Host LED Green Indicates that the Ranger 2244 system is properly enumerated on the host PC LED blinks when in suspend mode 6 Activity LED Amber Indicates a...

Страница 7: ...cate the USB device s 3 If you are using surface cabling the Ranger 2244 supports a maximum distance of 10km over SMF OR If you are using premise cabling ensure compatible fiber optic cabling is installed between the two locations with fiber optic information outlets located near both the computer and the USB device s and the total length including patch cords is no more than 10km over SMF Install...

Страница 8: ...f the Link LED is permanently off then the cabling between the LEX and REX unit is not installed properly or is defective 2 For Windows users 2000 XP Vista Windows 7 open Device Manager to confirm that the Ranger 2244 has installed correctly Expand the entry for Universal Serial Bus controllers by clicking the sign If the Ranger 2244 has been installed correctly you should find it listed as a Gene...

Страница 9: ...o resolve the problem after following these instructions please contact technical support for further assistance PROBLEM CAUSE SOLUTION All LEDs on LEX unit are off The LEX unit is not receiving enough power from the USB port or the optional LEX AC adapter 1 Ensure that the USB connection between the LEX and host computer is properly installed 2 Move the USB connector to another USB port on the ho...

Страница 10: ...rom Suspend Standby mode see your operating system s documentation 2 Attach a USB device to the Ranger 2244 All LEDs on both the LEX unit and REX unit are on but the USB device does not operate correctly or is detected as an Unknown Device in the operating system The USB device is malfunctioning The computer does not recognize the USB device The application software for the device is not operating...

Страница 11: ... documentation and power your USB device with the additional USB device manufacturer supplied power supply if available Device LED is orange and units are no longer functioning Overcurrent condition has occurred because USB device draws more power than can be supplied per USB specification 500mA 1 Power cycle REX LED Host and LINK LEDs on LEX REX units blink intermittently Firmware mismatch betwee...

Страница 12: ... 1 7 mm centre positive jack Power available to USB device at REX unit 500 mA each port LEX unit USB connector 1 x USB Type B LEX unit Link connector 1 x Duplex LC REX unit Link connector 1 x Duplex LC REX unit USB connector 4 x USB Type A LEX unit dimensions 3 94 x 2 99 x 1 02 100 mm x 76 mm x 26 mm LEX power consumption 500 mA Maximum REX unit dimensions 3 94 x 2 99 x 1 02 100 mm x 76 mm x 26 mm...

Страница 13: ...rranty set forth in this agreement replaces all other warranties Icron Technologies Corporation expressly disclaims all other merchantability and fitness for a particular purpose and non infringement of third party rights with respect to the hardware Icron Technologies Corporation dealer agent or employee is authorized to make any modification extension or addition to this warranty Under no circum...

Страница 14: ...tem will be shipped to you at Icron Technologies Corporation s expense not later than thirty days after Icron Technologies Corporation receives the defective product Address the returned product to RMA Coordinator Icron Technologies Corporation 4664 Lougheed Highway Suite 221 Burnaby BC V5C 5T5 Canada Tel 604 638 3920 Contacting Sales Email sales icron com Tel 604 638 3920 Contacting Technical Sup...

Страница 15: ... to the Type A port on a computer or hub The Type B connector is used to attach the USB cable to a USB device Duplex LC When a crossover fiber optic cable is called for the cable has the transmit signal on one end connected to the receive signal at the other end USB Type A port USB Type A connector USB Type B port USB Type B connector RX TX ...

Страница 16: ...Icron Technologies Corporation 4664 Lougheed Highway Suite 221 Burnaby BC V5C 5T5 Canada Tel 604 638 3920 Fax 604 638 3930 www icron com ...

Отзывы: