Air Cleaner
- Cumulative Run Time default is 0 hours (OFF) and Calendar
Time is OFF. Values can range from 400-3600 hours for
Cumulative Run Time (in 100 hour increments), or Calendar Time
can be set to OFF, or 3-24 months (in 3 month increments).
INPUT DEALER INFO
Contractors are able to input Brand Name, Model Number, Contractor
Name, and Contractor Phone number into these screens. This way, the
owner could give this information to the contractor so that he would know
what system the owner has prior to the service visit.
INPUT DEALER INFO
BRAND NAME
MODEL NUMBER
CONTRACTOR NAME
CONTRACTOR PHONE
SAVE
SELECT OPTION
∇∆
⊲
PREVIOUS
BRAND NAME
DEALER INFO
BRAND NAME
USE
∇∆
TO SCROLL
THRU CHARACTERS
A
_____________________________
CHANGE LETTER
∇∆
⊲
PREVIOUS
A
1.
Scroll to the info you want to enter and press the center button
■
.
2.
Enter the information by scroll through the characters using the up &
down arrows
▲▼
. Once the character you want is set, press the right
arrow
►
to move to the next space and begin entering another character.
3.
Once you’ve completed filling out the field, press the center button
■
to
save the entry and return to the INPUT DEALER INFO screen. Repeat
this process for all fields you want saved.
4.
Once all fields have been entered, scroll to SAVE and press the center
button
■
.
FAN WITH HEAT OPTION
Options are ON or OFF. This selection determines whether G (fan) output
is to be ON or OFF when W (auxiliary heat) output is ON in dual fuel
applications.
HUMIDIFY/DEHUMIDIFY OPTION
If your system is setup with a humidifier, or a dehumidification option, select
the appropriate setting.
HUMIDIFY ONLY
DEHUMIDIFY ONLY
NONE
To adjust the Set Point for Humidification or Dehumidification, Select the RH
from the Main menu. The values can be selected and adjusted from that screen.
NOTE: If you have an outdoor sensor attached to the thermostat, the
Humidification setting is adjusted automatically based on the outdoor
temperature.
REVERSING VALVE OPTION
Option of the reversing valve (O/B output) being on when in cooling or
heating. Default is COOLING.
RESTORE DEFAULTS
This will allow you to revert to the factory default settings. The
configuration settings will not rest when this option is used.
1
Review PROGRAM and HOLD sections to know effects of changing the set point