3.7 ENGINE FAILURE DURING GROUND ROLL
Magneto switches
OFF
Master switch
OFF
Throttle
Idle
Fuel valve
Shut-off
Brake
Fully applied
Immediately after lift off
Airspeed
Keep 60 mph IAS and first notch of flap
Eventual landing
Check for adequate spaces within 30° left and
30° right
Throttle
50%, fuel pump ON and try to restart the engine
If previous point fails
Before touching the ground, magnetoes OFF,
master switch OFF, throttle idle, fuel valve shut
off
Flaps
Fully extended
On the ground
brake as necessary
3.8 ENGINE START DURING FLIGHT
Throttle
Idle
Magneto switches
ON
Master switch
ON
Fuel pump
ON
Restart the engine
---------
RPM
As needed