C-10
ICP Flash Utility (IFU)
b
Updating the Flash on Multiple Controllers
—To flash the
firmware on multiple controllers, type:
ifu update /C <
controller_number_a
>,<
controller_number_b
>
Where
<controller_number_a>
and
<controller_number_b>
is the number of one of the controllers whose firmware you
are updating.
To upgrade controllers 0, 2, and 3 for example, type:
ifu update /C 0, 2, 3
c
Updating the Flash on All Controllers Simultaneously
—To
flash the firmware on all controllers, type:
ifu update /C all
Note:
The UFI file identifies the appropriate controllers,
so you do not have to worry about flashing the wrong
controller.
8
The IFU prompts you to insert the first firmware disk.
When it detects that the disk is in the drive, the IFU reads the
firmware image contained on the first disk.
9
When prompted, remove the first firmware disk and insert the
second firmware disk.
10
If necessary, repeat