Hardware Installation

2.5

Configurable Disk Drive SCSI Parameters

When a SCSI hard disk drive is initialized the first time by the RAID controller, its SCSI 
parameters are automatically set to their optimal settings. Most settings are set 
automatically and can not be configured manually. To view or configure disk drive SCSI 
parameters from the Storage Console, choose Advanced Setup 

Æ

 Configure Physical 

Devices 

Æ

 Select Physical Drive 

Æ

 SCSI Parameter/Initialize.

2.6

Configurable I/O Controller SCSI Parameters

When the controller starts up, its SCSI parameters are automatically set to their optimal 
settings. Manual configuration is not required. However, you can customize I/O SCSI 
parameters for each channel on the controller by using the Storage Console menu 
Advanced Setup > Configure Controller > Controller Settings.

Table 2-1. Configurable Disk Drive SCSI Parameters

Parameter

Setting/

Value

Configuration

Description

Synch. 

Transfer

Enabled /

Disabled

Automatic

This setting when enabled allows the controller to 
operate in synchronous transfer mode

Synch. 

Transfer Rate

Speed

(MB/sec)

Automatic

Allows for the setting of the speed for the SCSI 
hard disks (up to 320 MB/sec for U320 drives). 
No matter the setting, the SCSI bus will negotiate 
the fastest speed up to this setting. Lowering the 
setting will force the disk drive to transfer at the 
lower speed.

Disconnect

Enabled / 

Disabled

Automatic

Enabling this setting allows for the disk drive to 
disconnect from the SCSI bus when it’s not 
participating in a transfer. This allows for optimal 
bus utilization by all devices on the bus.

Tagged 

Queues

On / Off

Automatic

When enabled, this feature allows the SCSI disk 
drive to execute more than one command at a 
time.

Disk Read 

and Write 

Cache

On / Off

Configurable

For performance reasons, the 

Read Ahead and 

Write cache of the hard disk drives should always 
be on. This is the default setting.

Table 2-2. Configurable I/O Controller SCSI Parameters

Parameter

Setting/Value

Description

Domain Validation

On / Off

When this is set to 

On, Domain validation allows for a 

cyclical check of the correct data transfer at a given rate for 
the respective channel.

For ultra320, the GDT8500RZ controller supports Basic, 
Enhanced, and Margined Domain Validation. For ultra160, 
the GDT8500RZ controller supports Basic and Enhanced 
Domain Validation.

Содержание GDT8500RZ

Страница 1: ...ICP RAID Controller GDT8500RZ Hardware Installation and User s Guide Version 1 1 6 April 2003...

Страница 2: ...e time of writing ICP vortex and or its suppliers accept no liability for the implementation of these methods within the user s environment The user is responsible for and must satisfy itself that any...

Страница 3: ...Configurable Disk Drive SCSI Parameters 14 2 6 Configurable I O Controller SCSI Parameters 14 3 Hardware Specifications and Features 3 1 ICP RAID Controller Hardware Features 15 3 1 1 Key Features 15...

Страница 4: ...into a Computer System 13 Tables 2 1 Configurable Disk Drive SCSI Parameters 14 2 2 Configurable I O Controller SCSI Parameters 14 3 1 Hardware Architecture Features 15 3 2 Electrical Specifications...

Страница 5: ...e covers instructions for installing an ICP RAID controller and provides a guide to its features and specifications For a particular ICP RAID controller its hardware guide documents compatible RAID ad...

Страница 6: ...e quick start poster are provided on the CD ROM in both PDF and HTML format HTML To view online HTML documents Click Documentation from the autorun menu or open cdromdrive docs index htm PDF Portable...

Страница 7: ...d when correctly integrated per this guide complies with the following safety and electromagnetic compatibility EMC regulations 1 4 2 Product Safety Compliance CE Low Voltage Directive 73 23 EEC Europ...

Страница 8: ...uipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help If you m...

Страница 9: ...EEC 73 23 EEC Svenska Denna produkt har tillverkats i enlighet med EG direktiv 89 336 EEC 73 23 EEC 1 5 Warnings and Cautions This guide and all associated guides in the user documentation set the Qu...

Страница 10: ...damage before handling the ICP RAID controller ESD can damage adapter card components Perform the described procedures in this guide only at an ESD workstation If no such station is available you can...

Страница 11: ...bout availability of RAIDIOS enabled PCI slots Warning Shock hazards may be present inside the computer in which this card is being installed Disconnect all power cords to the computer before the remo...

Страница 12: ...m Consult your system docs for the exact location of the RAIDIOS enabled PCI slot 4 Connect one end of the SCSI cable to the on board SCSI connector Connect the other end of the SCSI cable to the SCSI...

Страница 13: ...are Firmware Update or Firmware Recovery See Appendix A for more information 2 4 SCSI Termination Termination is critical when connecting SCSI devices together Connected SCSI devices are typically cal...

Страница 14: ...nsfer mode Synch Transfer Rate Speed MB sec Automatic Allows for the setting of the speed for the SCSI hard disks up to 320 MB sec for U320 drives No matter the setting the SCSI bus will negotiate the...

Страница 15: ...expansion without reboot RAID array roaming Instant availability and background initialization Automatic rebuild with private dedicated or pooled global hot fix spare drives Variable data strip size...

Страница 16: ...e Server Service Pack 6a or higher Novell NetWare 5 1 support pack 2a or higher Linux 2 4 kernel Red Hat Linux 7 1 Debian Linux 2 2r6 I O interface PCI RAIDIOS enabled PCI 2 2 compliant PCI Transfer R...

Страница 17: ...nel Ultra320 SCSI controller 3 3 1 Supported Hard Drive Technology The ICP RAID controller supports both Single ended SE and Low Voltage Differential LVD devices but it is recommended that you use onl...

Страница 18: ...m Cable Length meters 1 Adapter Maximum Devices per SCSI Channel Single Ended LVD SCSI 1 2 5 8 6 3 8 Fast SCSI 2 10 8 3 3 8 Fast Wide SCSI 20 16 3 3 16 Ultra SCSI 2 20 8 1 5 3 8 Ultra SCSI 2 20 8 3 N...

Страница 19: ...igration to newer controller models of the same IO technology with the same or higher firmware versions is also usually supported However downgrade to older firmware versions may cause problems and is...

Страница 20: ...ntroller There is a minimum of at least one host drive per array drive A host drive can only be associated with or reside on a single array drive Like array drives host drives can reside on hard disk...

Страница 21: ...2 Choosing Update vs Recover When programming the firmware you must decide whether an update or a full recovery is more appropriate If firmware recovery is required you may need to change a jumper se...

Страница 22: ...damage before handling the ICP RAID controller 2 Power off all system components and disconnect their power cords 3 Remove the cover from the system to gain access to the PCI slots 4 Remove the ICP RA...

Страница 23: ...mpting you to insert a blank floppy diskette 9 Verify that a blank diskette is inserted then press Enter Table A 2 FRUU Locations and Descriptions FRUU Location Summary More Information Run the FRUU o...

Страница 24: ...rom http www icp vortex com or http www vortex de and copy it to a second floppy diskette Proceed to Section A 4 3 for information on running the FRUU OR Insert a second blank diskette into the comput...

Страница 25: ...p 4 above Refer to Section A 3 to set the jumper in reset mode If the controller state is RESET You can perform a firmware recovery If you only need to perform a firmware update shut down the system a...

Страница 26: ...py the firmware file and ICPCON onto the disk 2 With the adapter installed in the system start the new ICPCON under your OS 3 Select the applicable RAID controller and press Enter 4 If the Express Set...

Страница 27: ...and select the applicable RAID controller to view its new firmware version at the bottom of the console for example FW 2 34 yy Rzzz You can also use the OS version of ICPCON to update the firmware Ref...

Страница 28: ...28 Hardware Installation and User s Guide Flash Memory Programming...

Отзывы: