The nDO parameters in the following Modbus Address Tables are as follows: 
 

Model Name

 

Universal 

DIO

 

Number of DO channels

 

(nDO)

 

Number of DI channels(nDI)

 

ET-2242U

 

16 

 
 

 

(0xxxx) DO Address: 

Starting 
Address 

Points 

Description 

Bits Per 

Point 

Range 

Access 

Type 

(0x00) 

1 ~ nDO 

Digital Output Channels 

0 = Off   
1 = On 

R/W 

60 

(0x3C) 

Saves specific data to Flash 
(The  access  type  for  some  registers  is 
labeled with an “

E”

1 = Clear 

100 

(0x64) 

1 ~ nDO 

Enables the PWM for all DO Channels   

0 = Off   
1 = On 
(Default= 0) 

R/W 

235 

(0xEB) 

1 ~ nDO 

Sets  the  Power-on  value  for  all  DO 
Channels 

0 = Off 
1 = On 
(Default= 0) 

R/W/F 

267 

(0x10B) 

1 ~ nDO 

Sets the Safe value for all DO Channels 

0 = Off 
1 = On 
(Default= 0) 

R/W/F 

R

”: Read, “

W

”: Write, “

F

”: Settings are recorded in flash by default, “

E

”: After writing DO[60] register, the 

data will be stored in flash. 
 

 

 

 

For detailed information related to DO Modbus Addresses, refer to Section 6.3 "Modbus 
Register Table" in the ET-2200 User Manual, which can be found at: 
CD:\NAPDOS\ET2200\document\ 
http://ftp.icpdas.com/pub/cd/6000cd/napdos/et2200/document/ 

 

 

4

4

4

 

 

 

Содержание ET-2242U

Страница 1: ...ttp ftp icpdas com pub cd 6000cd napdos software esearch windows Double click the eSearch_vxxx_setup exe file icon to execute the driver installation Click the Next button to start the installation Se...

Страница 2: ...m Page 2 P Pi in n A As ss si ig gn nm me en nt ts s a an nd d W Wi ir ri in ng g N No ot te es s Pin Assignments Wire Connections Digital Output ON State Readback as 1 OFF State Readback as 0 Sink DO...

Страница 3: ...The access type for some registers is labeled with an E 1 1 Clear W 100 0x64 1 nDO Enables the PWM for all DO Channels 1 0 Off 1 On Default 0 R W 235 0xEB 1 nDO Sets the Power on value for all DO Cha...

Страница 4: ...rewall is properly configured to allow incoming connections or temporarily disable these functions otherwise the Search Servers function in the eSearch Utility described in Section 7 may not perform a...

Страница 5: ...e External Power 24V to the DO0 Pin06 Connect the External Power GND to the DO COM Pin04 6 6 6 1 Use the blade of the flat head screwdriver to push down the wire clamp Insert the wire Continue holding...

Страница 6: ...for the IP Address Subnet Mask and Gateway etc and then click the OK button The new settings for the ET 2242U will take effect within 2 seconds If the correct network configuration information is unk...

Страница 7: ...ogin screen is displayed enter the password in the login password field use the default password is Admin and then click the Submit button to enter the configuration web page The main Home page will b...

Страница 8: ...l la at te ed d I In nf fo or rm ma at ti io on n ET 2242U Product Page http www icpdas com root product solutions remote_io ethernet_io petl 7000_tpet_tet et 2242 html Documentation Firmware CD Napdo...

Отзывы: