5
Setting
up
the
ZT
‐
USB
Series
5.1
Introduction
of
configurations
1.
“Pan ID” is the group identity of a ZigBee network, and must be the same if they
are in the same ZigBee network.
(Valid values range from 0x0000 to 0x3FFF)
2.
“Node ID” is the identity of the ZigBee module.
The identity number must be unique if it is in the same ZigBee network as other
ZigBee module. (Valid values range from 0x0001 to 0xFFF7 for a ZigBee Router,
but is fixed to 0x0000 for a ZigBee Coordinator)
3. “RF Channel” indicates the radio frequency channel, and must be set to the same
.
channel if the module is in the same ZigBee network as other ZigBee modules
Channel
0x00
0x01
……
0x0F
Frequency(MHz) 2405
2410
……
2480
※
In addition, the RF channels 0x04, 0x09, 0x0E and 0x0F are recommended because
they are not covered with the frequency of Wi-Fi.
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
802.11b/g
Channel
1
802.11b/g
Channel
6
802.11b/g
Channel
11
802.11b/g
Channel
(North
America)
802.15.4
Channel
2400
MHz
2485
MHz