ZT-2551 - RS-485/RS-232 to ZigBee Slave Converter
- QuickStart (Apr/2017)
ICP DAS USA, Inc.
| 1-310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717
2
Overview of the ZT‐255x Configurations Options/Parameters
1. “
Pan ID
” is the group identity of a ZigBee network, and must be the same if
they are in the same ZigBee network.
3
Introduction of configurations
(Valid values range from 0x0000 to 0x3FFF)
2. “
Node ID
” is the identity of the ZigBee module.
The identity number must be unique if it is in the same ZigBee network as
other ZigBee module. (Valid values range from 0x0001 to 0xFFF7 for a
ZigBee Router, but is fixed to 0x0000 for a ZigBee Coordinator)
3. “
RF Channel
” indicates the radio frequency channel, and must be set to the
same channel if the module is in the same ZigBee network as other ZigBee
modules.
Channel
0x00
0x01
2410
……
……
0x0F
2480
Frequency(MHz) 2405
Use application tools or analyzers to detect the wireless signal, chose a RF
Channel which has not been occupied. E.g. Wifi Analyzer
As below the screenshot shown, there were several WLANs over the channel
1, 6 and 11. Referring to the channel table of WiFi and ZigBee, the channels
of ZigBee 4, 9, E and F are not overlap with WLAN. So, the RF Channel 4, 9,
E and F of ZigBee are recommended in this case.