background image

Tiny Addressable Serial Converter  

ICP DAS CO., LTD. 

 

User Manual, Ver. 1.3, Apr. 2018, Page: 20

 

 

Step 3: Search for the tM-752N module 

 
Click the “

Search Servers

” button to search for your tM-752N module. 

 

 

 
 
 

Step 4: Configure the network settings 

 
1.

 

tM-752N  series  module is  IP-based devices that may not be suitable for your network 
using a default IP address. Therefore, you must first assign a new IP address to the tM-
752N module depending on your network settings. 

 

 

Double Click 

Содержание tM-752N Series

Страница 1: ...reserves the right to change this manual at any time without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for it...

Страница 2: ...MENTS 15 2 7 WIRING NOTES 16 3 SETTING UP THE TM 752N 17 STEP 1 CONNECTING THE POWER AND HOST PC 17 STEP 2 RUN THE ESEARCH UTILITY 19 STEP 3 SEARCH FOR THE TM 752N MODULE 20 STEP 4 CONFIGURE THE NETWO...

Страница 3: ...41 5 1 5 AAON stop bit 43 5 1 6 AA6 name 45 5 1 7 AA7 46 5 1 8 AAC delimiter 47 5 1 9 delimiter AA bypass 49 5 1 10 AAKV 50 5 1 11 AATN CrLfmode 52 5 1 12 AAM 54 5 1 13 AAU 55 5 1 14 AAJN timeout 57...

Страница 4: ...ymodules napdos tM 752N document Firmware http ftp icpdas com pub cd tinymodules napdos tM 752N firmware eSearch Utility http ftp icpdas com pub cd tinymodules napdos software esearch tM 752N Product...

Страница 5: ...232 devices via a single RS 485 network This network protocol offers stability reliability and simple cabling while delivering a low cost easy to maintain product To achieve maximum space savings the...

Страница 6: ...nds to the destination RS 232 device Responses from the local RS 232 devices will be returned to the Host PC via the tM 752N module 1 2 Self Tuner ASIC Inside The built in Self Tuner ASIC on an RS 485...

Страница 7: ...ver Web server enables configuration of the tM 752N via a standard web browser interface e g Internet Explorer Firefox or Mozilla etc This means that it is easy to check the configuration of thetM 752...

Страница 8: ...3 wire RS 232 COM3 3 wire RS 232 Self Tuner Yes automatic RS 485 direction control RS 485 Bias Resistor Yes 10 K Node 32 max UART 16c550 or compatible COM Port Format Baud Rate 115200 bps Max Data Bi...

Страница 9: ...scovery Allows easy firmware update via the Ethernet Built in Web server for easy configuration Terminal block connector for easy wiring Tiny form factor and low power consumption RoHS compliant and n...

Страница 10: ...Ver 1 3 Apr 2018 Page 10 2 4 Front View Here is a brief overview of the tM 752N series module components and a description 5 J2 Connector 3 S1 System LED Indicator 4 Operating Mode Switch 1 Ethernet P...

Страница 11: ...lluminated When power is supplied via PoE Power over Ethernet the PoE LED Green indicator will be illuminated 2 12 VDC 48 VDC Jack The tM 752N is equipped with a 12 48 VDC jack that is used as the pow...

Страница 12: ...in the Run position by default When updating the tM 752N firmware the switch needs to be moved from the Run position to the Init position The Switch must be returned to the Run position after the upda...

Страница 13: ...iagrams provide the dimensions of thetM 7521 tM 7522and CA 002 cable that can be used as a reference when defining the specifications and the DC power supply plug for any custom enclosures All dimensi...

Страница 14: ...O LTD User Manual Ver 1 3 Apr 2018 Page 14 CA 002 Cable Pin Assignment P1 P2 1 RED OPEN 2 BLACK OPEN Note Cable color BLACK NO DESCRIPTION QTY UNIT 1 UL2464 18AWG 2C RED BLACK 0D5 0 COLOR BLACK 1 PCS...

Страница 15: ...ter ICP DAS CO LTD User Manual Ver 1 3 Apr 2018 Page 15 2 6 Pin Assignments 1 Port 2 Wire RS 485 and 1 Port 5 Wire RS 232 Module 1 Port 2 Wire RS 485 and 2 Port 3 Wire RS 232 Module tM 7521 Pin Assign...

Страница 16: ...nation resistor connected across the two wires DATA and DATA Typically 120 resisters are used 4 The Data and B pins are positive voltage pins and Data and A pins are negative voltage pins in the above...

Страница 17: ...onal Isolated RS 232 to RS 422 485 converter module I 7520 module optional Step 1 Connecting the power and Host PC 1 Check Init Run switch is on Run position 2 Connect both the tM 752N and your comput...

Страница 18: ...ny Addressable Serial Converter ICP DAS CO LTD User Manual Ver 1 3 Apr 2018 Page 18 3 Perform a test wiring check as follows Wiring to RS 232 Device Wiring to host PC Via the RS 485 bus PoE Power Supp...

Страница 19: ...Ver 1 3 Apr 2018 Page 19 4 Connecting to Multiple Remote RS 232 Devices as follows Step 2 Run the eSearch Utility The eSearch Utility can be obtained from our FTP site http ftp icpdas com pub cd tiny...

Страница 20: ...the Search Servers button to search for your tM 752N module Step 4 Configure the network settings 1 tM 752N series module is IP based devices that may not be suitable for your network using a default...

Страница 21: ...r to obtain the correct network configuration information such as IP Mask Gateway Enter the network settings and then click OK The tM 752N will use the new settings within 2 seconds 3 Wait 2 seconds a...

Страница 22: ...rom our FTP site http ftp icpdas com pub cd tinymodules napdos software 2 Check that the configuration of the COM Port is correct and then click the Open COM button 4 Type a string in the send field t...

Страница 23: ...ectly 4 1 Logging on to the tM 752N Web Server You can log onto the tM 752N web server from any computer that has Internet access Step 1 Open a browser Mozilla Firefox Google Chrome and Internet Explo...

Страница 24: ...tering the IP address the login dialog page will be displayed Enter the password and then click the Submit button to enter the configuration web page The factory default password is Step 4 Welcome to...

Страница 25: ...1 3 Apr 2018 Page 25 4 2 Home Page The Home link connects to the main page which contains two parts The first part of this page provides basic information about the tM 752N hardware and software The s...

Страница 26: ...stem Timeout Note After updating the tM 752N firmware you can check the version information on this page 4 3 2 IP Address Selection The Address Type Static IP Address Subnet Mask and Default Gateway i...

Страница 27: ...automatically assigns an IP address to each device Please refer to Section 4 3 2 2 Dynamic Configuration Static IP Address Each tM 752N on the network must have a unique IP address This item used to...

Страница 28: ...ll the network settings in the following manner Step 1 Select Static IP as the address type Step 2 Enter the appropriate network settings Step 3 Click the Update Settings button to finish the configur...

Страница 29: ...able default 1 Enable 0 Enable Response Prefix Add the prefix code in front of response message 0 Alias Name Each tM 752N can be allocated a unique Alias name so that it can be identified the network...

Страница 30: ...hese steps Step 1 Click the Restore Defaults button to reset the configuration Step 2 Click the OK button in the message dialog box Step 3 Check whether the tM 752N is reset to factory default setting...

Страница 31: ...Port Settings 4 4 1 Port1 Settings Check the tM 752N hardware and software information The port settings provide the following functions These are 5 modes in ending chars pattern Mode 0 0x0D Mode 1 0x...

Страница 32: ...on The number of User defined ending char can be 1 2 chars For example 1 char 1 0x0D 2 chars 2 0x0D 0x0A 4 Delimiter This is a special symbol placed in the front of command response message can be use...

Страница 33: ...ist restricts the access of packets based on the IP header If one or more IP address are saved into the IP filter table only clients whose IP is specified in the IP filter list can access the tM 752N...

Страница 34: ...tions Item Description Current password Enter the old password default is admin New password Enter the new password Confirm new password Enter the new password again Submit Click this button to save t...

Страница 35: ...top bit AA stop bit Read Set the Stop Bit for COM 1 2 3 5 1 6 AA6 ID AA Set the alias name string for COM 2 3 5 1 7 AA7 AA ID Read the alias name string for COM 2 3 5 1 8 AAC delimiter AA delimiter Re...

Страница 36: ...alid range is from 00 FF 2 character checksum If the checksum is disabled no chk End Character Response Byte 1 Byte 2 3 Byte 4 5 Byte 6 7 Note AA chk CrLf Valid Invalid AA chk CrLf Delimiter character...

Страница 37: ...om 00 FF 0 Read Set the Baud Rate for the COM 1 1 Read Set the Baud Rate for the COM 2 3 Valid values are 1200 2400 4800 9600 19200 38400 57600 115200 2 character checksum If the checksum is disabled...

Страница 38: ...Page 38 Example Assume the module address of tM 752N is 01 e g Command Response 1 01B0 CrLf 0157600 CrLf Read the COM1 RS 485 Baud Rate 2 01B19600 CrLf 01 CrLf Changes the COM2 RS 232 Baud Rate to 960...

Страница 39: ...ter port address in Hex format The valid range is from 00 FF 0 Reads Sets the data bit for the COM 1 1 Reads Sets the data bit for the COM 2 3 Valid values are 5 6 7 8 2 character checksum If the chec...

Страница 40: ...age 40 Example Assume the module address of tM 752N is 01 e g Command Response 1 01D08 CrLf 01 CrLf Changes the data bit to 8 for the COM1 RS 485 2 01D17 CrLf 01 CrLf Changes the data bit to 7 for the...

Страница 41: ...iter character 2 character port address in Hex format The valid range is from 00 FF 0 Reads Sets the parity bit for the COM 1 1 Reads Sets the parity bit for the COM 2 3 0 NONE 1 EVEN 2 ODD 3 MARK 4 S...

Страница 42: ...18 Page 42 Example Assume the module address of tM 752N is 01 e g Command Response 1 01P00 CrLf 01 CrLf Changes parity bit to NONE for COM1 RS 485 2 01P10 CrLf 01 CrLf Changes parity bit to NONE for C...

Страница 43: ...ter character 2 character port address in Hex format The valid range is from 00 FF 0 Reads Sets the stop bit for the COM 1 1 Reads Sets the stop bit for the COM 2 3 Valid values are 1 2 2 character ch...

Страница 44: ...LTD User Manual Ver 1 3 Apr 2018 Page 44 Example Assume the module address of tM 752N is 01 e g Command Response 1 01O12 CrLf 02 CrLf Changes the stop bit to 2 for the COM2 RS 232 2 02O12 CrLf 03 CrLf...

Страница 45: ...ber of character is 15 2 character checksum If the checksum is disabled no chk End Character Response Byte 1 Byte 2 3 Byte 4 5 Byte 6 7 Note AA chk CrLf Valid Invalid AA chk CrLf Delimiter character i...

Страница 46: ...e 4 10 Byte 11 12 Byte 13 14 Note AA name chk CrLf Read Byte 1 Byte 2 3 Byte 4 5 Byte 6 7 Note AA chk CrLf Invalid AA name chk CrLf Delimiter character indicating a valid command Delimiter character i...

Страница 47: ...rite AA delimiter chk CrLf Delimiter character 2 character port address in Hex format The valid range is from 00 FF Default delimiter is 2 character checksum If the checksum is disabled no chk End Cha...

Страница 48: ...Assume the module address of tM 752N is 01 e g Command Response 1 01C CrLf 01 CrLf Reads the delimiter for the COM2 RS 232 2 02C CrLf 02 CrLf Changes the delimiter for the COM3 RS 232 Notes 1 The del...

Страница 49: ...limiter AA bypass chk CrLf AA bypass chk CrLf 2 characterport address in Hex format The valid range is from 00 FF The data string sent to COM 2 3 2 character checksum If the checksum is disabled no ch...

Страница 50: ...character module address in Hex format The valid range is from 00 FF 0 checksum disabled 1 checksum enabled 2 character checksum If the checksum is disabled no chk End Character Response Byte 1 Byte...

Страница 51: ...dule address of tM 752N is 01 e g Command Response 1 01K000 CrLf 0182 CrLf Disables the checksum chk 00 82 2 01K1 CrLf 01 CrLf The checksum is enabled Notes The checksum enable disable function is val...

Страница 52: ...mand response string Request Byte 1 Byte 2 3 Byte 4 Byte 5 Byte 6 7 Byte 8 9 Note AA T N chk CrLf Read Byte 1 Byte 2 3 Byte 4 Byte 5 Byte 6 Byte 7 8 Byte 9 10 Note AA T N CrLfmode chk CrLf Write AA N...

Страница 53: ...ndicating an invalid command 2 character port address in Hex format 2 character checksum If the checksum is disabled no chk End Character If No response syntax error communication error or address err...

Страница 54: ...racter Response Byte 1 Byte 2 3 Byte 4 6 Byte 7 8 Byte 9 10 Note AA name chk CrLf Read Byte 1 Byte 2 3 Byte 4 5 Byte 6 7 Note AA chk CrLf Invalid AA name chk CrLf Delimiter character indicating a vali...

Страница 55: ...reds of RS 232 devices without any loss of data in short period Buffer operation rules Rule 1 The buffer is enabled after being powered on Rule 2 The delimiter AA command disables the buffer operation...

Страница 56: ...a new extension of the AAU command added in firmware version B1 1 3 for the tM 752N modules When there is no data in the serial buffer from slave device the AAU command causes no response from tM 752...

Страница 57: ...AAJN chk CrLf Reads the timeout value AAJN timeout chk CrLf Sets the timeout value Request Byte 1 Byte 2 3 Byte 4 Byte 5 Byte 6 7 Byte 8 9 Note AA J N chk CrLf Read Byte 1 Byte 2 3 Byte 4 Byte 5 Byte...

Страница 58: ...x format 2 character checksum If the checksum is disabled no chk End Character If no response buffer is empty syntax error communication error address error Example Assume the module address of tM 752...

Страница 59: ...port address in Hex format The valid range is from 00 FF 0 Prefixed address byte disabled 1 Prefixed address byte enabled 2 character checksum If the checksum is disabled no chk End Character Respons...

Страница 60: ...OM1 The prefixed address byte is disabled 2 01E1 CrLf 01 CrLf Sets the status of the prefixed address byte to enable Notes If the prefixed address byte is enabled the response for delimiter AA bypass...

Страница 61: ...Addressable RS 232 Controller Command Type Each tM 752N module has a unique address The Host PC first sends a command to all tM 752Nseries modules The destination tM 752Nmodule will pass the command t...

Страница 62: ...e barcode reader can scan a barcode at anytime and the tM 752Nmodule will store these barcodes in an internal buffer 1K bytes The Host PC first sends AAU command to each tM 752N modules one by one The...

Страница 63: ...support two RS 232 devices AA and AA 1 The Host PC first sends a command to each tM 7522 modules one by one The destination tM 752N module will pass the command to its local RS 232 device 1 or RS 232...

Страница 64: ...factory default values after the module is reset Step 1 Locate the Init Run switch that can be found on the right hand side of the tM 752N module and set it to the Init position Reboot the module to...

Страница 65: ...er UDP dialog box and modify the basic settings as necessary e g the IP Mask and Gateway addresses and then click the OK button to save the new settings Step 4 Reset the Init Run switch on the tM 752N...

Страница 66: ...revision history Revision Date Description 1 0 Nov 2011 Initial issue 1 1 1 Aug 2014 Updated the information about the Firmware Version v1 0 4 Jul 13 2012 in Chapter 4 Web Configuration 1 2 Aug 2017 1...

Отзывы: