background image

 

34 

 

(8)  According the Port I / O of VxComm Utility to select the com port of RMV-514 

Utility, then click "RMV-514 Utility => Connect" 

 

 

 

 

(9)  The remaining steps, please refer to Chapter 4   

 

RMV-514 

ГК

 

Атлант

 

Инжиниринг

 – 

официальный

 

представитель

 

в

 

РФ

 

и

 

СНГ

 

+7(495)109-02-08 [email protected] www.bbrc.ru 

Содержание RMV-514

Страница 1: ...elligent Multiport Serial to GPRS Gateway with I O User manual V1 1 GPRS Network Internet Public Fixed IP G P R S VxServer VxComm Driver User s software RMV 514 RS 485 network Flow meter Seismic senso...

Страница 2: ...mation furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use or for any infringements of patents or other rights of third parties res...

Страница 3: ...Menu 21 4 3 Connecting to the RMV 514 21 4 4 Parameters 22 4 5 Download Upload Parameters 23 4 6 I O Monitor 24 4 7 System 25 4 7 1 Signal Quality 25 4 7 2 Reboot the RMV 514 25 4 7 3 Inputting the PI...

Страница 4: ...is broke the GPRS network by something happened It also supports remote I O monitor via virtual COM by Modbus RTU protocol M2M solution will improve the service quality and reduce operating costs Many...

Страница 5: ...Internet Public Fixed IP GPRS G P R S G P R S VxServer VxComm Driver PLC Software RMV 514 RS 485 PLC RMV 514 RS 485 PLC RMV 514 RS 485 PLC 1AI 3DO 6DI 1AI 3DO 6DI 1AI 3DO 6DI Remote serial devices mon...

Страница 6: ...ports Utility port RS 232 TxD RxD GND use for device configuration and debug COM1 RS 485 D D use for communication with other devices Baud Rate 2400 4800 9600 19200 38400 57600 and 115200 bps Digital...

Страница 7: ...Hi Pot Required Supply Voltage 10 VDC 30 VDC Mechanical Casing Plastic Flammability UL 94V 0 materials Dimensions W x L x H 91 mm x 132 mm x 52 mm Installation DIN Rail Environmental Operating Temper...

Страница 8: ...DI5 DI COM 07 DI COM DO PWR 08 DO PWR DO 09 DO0 10 DO1 DO GND 11 DO GND N A 12 N A Ain 13 Ain Ain 14 Ain COM Port Power Input Terminal No Pin Assignment Ground for COM 01 GND Utility Port RS 232 02 Rx...

Страница 9: ...9 2 3 Dimensions 7 495 109 02 08 sales bbrc ru www bbrc ru...

Страница 10: ...10 2 4 DI DO internal Structure and Wire Connection 1 DI Internal Structure 2 DO Internal Structure 7 495 109 02 08 sales bbrc ru www bbrc ru...

Страница 11: ...as the following 2 GSM Green The modem LED can indicate the status of GSM module 3 STA Orange The system LED indicated whether the RMV 514 is normal of failed The Power is active The Power is not act...

Страница 12: ...tenna B Plug in the normal SIM card Before apply the SIM card confirm it is OK by mobile phone C Pin08 and Pin09 connect to the DC VS and DC GND of the power supply D Follow the section 2 4 to wire th...

Страница 13: ...mework 2 0 or above in the PC the section 3 1 can be omitted Microsoft Net Framework Version 2 0 http www microsoft com downloads details aspx FamilyID 0856ea cb 4362 4b0d 8edd aab15c5e04f5 DisplayLan...

Страница 14: ...14 1 Press Next to the next step 2 Select the I accept the terms of the License Agreement and Install to the next step 7 495 109 02 08 sales bbrc ru www bbrc ru...

Страница 15: ...15 3 The installation process would be going 4 After finishing the installation press Finish to exit the program 7 495 109 02 08 sales bbrc ru www bbrc ru...

Страница 16: ...RMV 514 Software RMV 514_Utility_Setup_Vx xx exe The installation figure is as follows 1 Press Next to start the installation procedure 2 Select the installation path The default path is C ICPDAS RMV...

Страница 17: ...17 3 Select the Start Menu Folder Press Next to the next step 4 Select additional tasks Press Next to the next step 7 495 109 02 08 sales bbrc ru www bbrc ru...

Страница 18: ...18 5 Click Install to start to install the RMV 514 Utility 6 Click Finish to finish installing RMV 514 Utility 7 495 109 02 08 sales bbrc ru www bbrc ru...

Страница 19: ...14 Utility The description is as the following 1 Project The parameters of the RMV 514 can be saved as the project file The operation functions include New Open Save Save as and etc 2 Exit Exit the RM...

Страница 20: ...Parameter groups There are four parameter groups in the RMV 514 Utility including System and COM Port 3 Parameters Show or set the parameters 4 Description A particular or minute account 5 Status Bar...

Страница 21: ...file If the parameters are changed or save the uploading parameters from the RMV 514 you can use this function to save these configurations Save as Saving the file as another name 4 3 Connecting to t...

Страница 22: ...ion Protocol RMV 514 support protocol Read only Address The address of the RMV 514 Read only Remote Server The remote VxServer server s IP or domain name Remote Server Port The remote VxServer server...

Страница 23: ...data when the length of a data more than fixed length 1 1000 2 Fixed end byte It is as complete a data when receives the fixed end byte Like CR 0x0d 0 255 Com End Param 4 5 Download Upload Parameters...

Страница 24: ...AI value It will automation get the IO status per 5 sec Text field A AI DI DO Monitor Online Get I O status succeed Offline Get I O status failed B DI0 DI5 DO0 DO1 Green The voltage logic is high Red...

Страница 25: ...ow the GSM signal strength Field Description The strength is divided into 5 sections shown in percentage Operation Read Read the GSM signal strength from the RMV 514 4 7 2 Reboot the RMV 514 Clicking...

Страница 26: ...ow would pop up as follows If the number of times for inputting the wrong PIN code is more than the allowed number the PIN code would be ineffective And the PUK code window would pop up 2 Asking for i...

Страница 27: ...5 Inquiring System status Press System System status in tool menu and the window would show the RMV 514 working status Field instruction Connect Status Connected Get RMV 514 status is succeed Disconne...

Страница 28: ...28 4 7 6 Inquiring Firmware Version Press System Firmware Version in tool menu and the window would show the versions of the RMV 514 Utility and firmware 7 495 109 02 08 sales bbrc ru www bbrc ru...

Страница 29: ...y Download Microsoft Net Framework Version 2 0 http www microsoft com downloads details aspx FamilyID 0856eacb 4362 4b0 d 8edd aab15c5e04f5 DisplayLang en Download VxServer software http m2m icpdas co...

Страница 30: ...0 5 2 Setting the VxServer and VxComm Driver 1 Verify that the device has been connected up 2 Execute VxComm Utility then click Search Servers RMV 514 RMV 514 7 495 109 02 08 sales bbrc ru www bbrc ru...

Страница 31: ...31 3 Select your device then click Add Server s 4 IP Range check Maps virtual COM ports to Port I O on servers RMV 514 RMV 514 7 495 109 02 08 sales bbrc ru www bbrc ru...

Страница 32: ...Options please follow the below parameter settings Parameters Fixed value Keep Alive Time 1 Connection Broken 3 Connect Timeout 1 Command Port 10000 Virtual I O Port 9999 7 495 109 02 08 sales bbrc r...

Страница 33: ...nfigure the system parameter via RMV 514 utility it can also get the I O status and control the DO I O control methods please refer the chapter 6 II Port 1 The Port 1 mapping to the COM1 of RMV 514 Po...

Страница 34: ...ding the Port I O of VxComm Utility to select the com port of RMV 514 Utility then click RMV 514 Utility Connect 9 The remaining steps please refer to Chapter 4 RMV 514 7 495 109 02 08 sales bbrc ru w...

Страница 35: ...uest 00 Net ID 1 Byte 01 Function code 1 Byte 02 03 Starting address 2 Byte 04 05 DO count 2 Byte Response 00 Net ID 1 Byte 01 Function code 1 Byte 02 Byte count of response B DO count 7 8 1 Byte 03 B...

Страница 36: ...5 00 1 Byte Response 00 Net ID 1 Byte 01 Function code 1 Byte 02 03 Starting address 2 Byte 04 FF High 00 Low 1 Byte 05 00 1 Byte 5 Set multi Digital Output Function code 15 Request 00 Net ID 1 Byte 0...

Страница 37: ...00 Read DI0 R 00001 0x01 Read DI1 R 00002 0x02 Read DI2 R 00003 0x03 Read DI3 R 00004 0x04 Read DI4 R 00005 0x05 Read DI5 R 3 AI status Function Code 4 Address Data Address Description Attribute 30027...

Отзывы: