5. DIP Switch 

 

No 

Switch Name 

Description 

 

1 ~ 3 

Group ID 

RFU-433  with  the  same 
group  ID  can  communicate 
with each other 

4 ~ 6 

reserved 

reserved 

7 ~ 8 

COM 

data type 

Data Type 

N, 8, 1 

OFF 

OFF 

O, 8, 1 

ON 

OFF 

E, 8, 1 

OFF 

ON 

Repeater 

ON 

ON 

 

 

Set mode/Run mode 

Set  Utility setting mode 

Run

 

Normal firmware work

 

 

6. RFU-433 Utility 

 

 

Users 

can select “Hardware Setting” or “Software Setting” through the utility. If 

use 

“Hardware Setting”, the “Channel” parameter will be fixed at 433.5 MHz, the 

“Output  Power”  parameter  will  be  fixed  at  10  dBm,  and  the  “Message  Duty” 
parameter will be fixed at enable 10% message duty. If use “Software Setting”, the 
“Channel”, “Output Power” and “Message Duty” parameters can be set by users. 

 