background image

 

PET-7H16M 

Quick Use Manual 

 

Version  1.0.3,  January  2023 

 
 
 
 
 
 

Service and usage information for 

 

 

 

 

 

 

 

 

 
 
 
 
 
 

Written by Sean 

Edited by Anna Huang 

PET-7H16M 

Содержание PET-7H16M

Страница 1: ...PET 7H16M Quick Use Manual Version 1 0 3 January 2023 Service and usage information for Written by Sean Edited by Anna Huang PET 7H16M...

Страница 2: ...through the HSDAQ Utility collecting PET 7H16M data and displaying the data in the utility chart 4 Program development VC NET program A brief description of the function calls process and program des...

Страница 3: ...T 7H16M module getting the power One is through Ethernet by a PoE switch the other is as usual through wiring by an external power POE Power Supply Connect PC to the Ethernet port via the PoE switch C...

Страница 4: ...d PET 7H16M The external power supply should be in the range of 12 VDC to 48 VDC Network Settings The factory default settings for the PET 7H16 network are as follows Item Default IP Address 192 168 2...

Страница 5: ...and install the HSDAQ Utility in the following path https www icpdas com tw download show php num 2327 2 Run HSDAQ Utility 3 Press choose Search from the Tools menu 4 The searched PET 7H16M module wil...

Страница 6: ...7H16M to be set and the following setting screen will appear 6 Write the new setting value in the IP address Mask Gateway Alias field and press the OK button 7 Wait for the PET 7H16M to reboot After...

Страница 7: ...ws the corresponding effective operating frequency range for the acquisition and trigger modes Acquisition Trigger Continuous N Sample Software AD 1 30 KHz 1 Hz 200 KHz External CLK AD 1 30 KHz Post T...

Страница 8: ...Data Acquisition mode The speed of the A D acquisition and the amount of data acquired are controlled by external electrical signals A falling edge for each output waveform triggers an AD conversion...

Страница 9: ...PET 7H16M Quick Use Manual P9 ii Post Trigger acquisition of N data samples In this mode the A D acquisition of the N data samples is started once the trigger signal is received...

Страница 10: ...be used as an entry test and a simple diagnostic Steps 1 Execute the HSDAQ Utility Enter the IP address of the PET 7H16M in the following screen and click the Connect button 2 Set the parameter value...

Страница 11: ...count the acquisition will stop automatically 2 6 After the above steps are completed press the Set button to write the setting value to the PET 7H16M module 3 Start AI high speed data acquisition 3...

Страница 12: ...7H16M Quick Use Manual P12 3 3 Select which data file to display 3 4 The top of the following UI is the waveform diagram drawn by the data Below is the data of each channel Each page displays 1000 da...

Страница 13: ...dll Used for Net programs User can get the SDK library files from web site the file path is as below https www icpdas com en download show php num 2326 Before using HSDAQ dll HSDAQNet dll you must in...

Страница 14: ...ps www icpdas com en download show php num 2599 In Section 1 4 1 learn more about developing C programs using SDK in Visual Studio In Section 1 4 2 learn more about developing VB NET programs using SD...

Страница 15: ...unction call flow please refer to the the HSDAQ API Reference manual in the following path Section 2 4 High Speed IO API https www icpdas com en download show php num 2599 The following two modes of h...

Страница 16: ...rate 30 KHz Trigger mode 0 0 Software trigger TargetCnt 0 0 Continuous mode Start data acquisition of scanning AI channels Determine how much data is in the buffer Read the data from the buffer Whethe...

Страница 17: ...ram hHS 8 0 0 20000 0 0 0 Set the AI scan parameter Sampling rate 20KHz Trigger mode 0 0 Software trigger TargetCnt 0 0 Continuous mode HS_StartAIScan hHS Start data acquisition of scanning AI channel...

Страница 18: ...PET 7H16M Quick Use Manual P18 HS_StopAIScan hHS Stop data acquisition HS_Device_Release hHS Release the device from system...

Страница 19: ...meter Sampling rate 1 200 KHz Trigger mode 0 0 Software Trigger TargetCnt 0 0 N Sample Mode Start data acquisition of scanning AI channels Determine total number of samples reaches the target count Re...

Страница 20: ...000000 0 0 Set the AI scan parameter Sampling rate 100KHz Trigger mode 0 0 Software trigger TargetCnt 2000000 2000000 samples for acquisition HS_StartAIScan hHS Start data acquisition of scanning AI c...

Страница 21: ...le of data in the buffer reaches the target count unsigned long size targetCnt readsize HS_GetAIBufferHex hHS WORD dataBuffer size Read the N sample of data from the buffer HS_StopAIScan hHS Stop data...

Страница 22: ...nd initialize the device Set the AI scan parameter Sampling rate 1 200 KHz Trigger mode 0 0 Software Trigger TargetCnt 10000 10000 Samples Start to record data on the scanning AI channel Obtain the ac...

Страница 23: ...mode 0 0 Software trigger TargetCnt 2000000 2000000 samples for acquisition HS_StartLogger hHS NULL 2 0 Start to record data on the scanning AI while ret HS_GetTotalSamplingStatus hHS ulleng triggerS...

Страница 24: ...ger hHS Stop data logging HS_Device_Release hHS Release the device from system Use the Data logger API function to read data log files HANDLE hlf TCHAR tcgetfulfilelPath MAX_PATH 0 int ind HS_GetAllLo...

Страница 25: ...PET 7H16M Quick Use Manual P25 rttime float fdatabuff float malloc sizeof float samplecount HS_GetLogFile_AIData hlf 0 samplecount fdatabuff HS_LogFile_Close hlf...

Страница 26: ...an easy to use interface and simplifies the programming process The HSDAQ LabVIEW toolkit provides an HSDAQ llb with basic sub VIs for controlling the HSDAQ devices and several demo programs to demons...